REBOA as a New Damage Control Component in Hemodynamically Unstable Noncompressible Torso Hemorrhage Patients
Authors:
- Carlos Alberto OrdoñezCOCarlos Alberto Ordoñez
- Michael ParraMPMichael Parra
- Yaset CaicedoYCYaset Caicedo
- Natalia PadillaNPNatalia Padilla
- Fernando RodriguezFRFernando Rodriguez
- Jose Julian SernaJSJose Julian Serna
- Alexander SalcedoASAlexander Salcedo
- Alberto GarciaAGAlberto Garcia
- Claudia Patricia OrlasCOClaudia Patricia Orlas
- Luis Fernando PinoLPLuis Fernando Pino
- David Alejandro MejiaDMDavid Alejandro Mejia
Open Access
- 22 October 2020
- journal article
- research article
- Published by Universidad del Valle in Colombia Medica
- Vol. 51 (4) , e4064506
Abstract
Noncompressible torso hemorrhage is one of the leading causes of preventable death worldwide. An efficient and appropriate evaluation of the trauma patient with ongoing hemorrhage is essential to avoid the development of the lethal diamond (hypothermia, coagulopathy, hypocalcemia, and acidosis). Currently, the initial management strategies include permissive hypotension, hemostatic resuscitation, and damage control surgery. However, recent advances in technology have opened the doors to a wide variety of endovascular techniques that achieve these goals with minimal morbidity and limited access. An example of such advances has been the introduction of the Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA), which has received great interest among trauma surgeons around the world due to its potential and versatility in areas such as trauma, gynecology & obstetrics and gastroenterology. This article aims to describe the experience earned in the use of REBOA in noncompressible torso hemorrhage patients. Our results show that REBOA can be used as a new component in the damage control resuscitation of the severely injured trauma patient. To this end, we propose two new deployment algorithms for hemodynamically unstable noncompressible torso hemorrhage patients: one for blunt and another for penetrating trauma. We acknowledge that REBOA has its limitations, which include a steep learning curve, its inherent cost and availability. Although to reach the best outcomes with this new technology, it must be used in the right way, by the right surgeon with the right training and to the right patient.Keywords
This publication has 32 references indexed in Scilit:
- Intraoperative combination of resuscitative endovascular balloon occlusion of the aorta and a median sternotomy in hemodynamically unstable patients with penetrating chest trauma: Is this feasible?Journal of Trauma and Acute Care Surgery, 2018
- Use of open and endovascular surgical techniques to manage vascular injuries in the trauma setting: A review of the American Association for the Surgery of Trauma PROspective Observational Vascular Injury Trial registryJournal of Trauma and Acute Care Surgery, 2018
- Expanding the field of acute care surgery: a systematic review of the use of resuscitative endovascular balloon occlusion of the aorta (REBOA) in cases of morbidly adherent placentaEuropean Journal of Trauma and Emergency Surgery, 2017
- Damage control resuscitation in patients with severe traumatic hemorrhageJournal of Trauma and Acute Care Surgery, 2017
- The AAST prospective Aortic Occlusion for Resuscitation in Trauma and Acute Care Surgery (AORTA) registryJournal of Trauma and Acute Care Surgery, 2016
- A small case series of aortic balloon occlusion in trauma: lessons learned from its use in ruptured abdominal aortic aneurysms and a brief reviewEuropean Journal of Trauma and Emergency Surgery, 2015
- Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) as an Adjunct for Hemorrhagic ShockJournal of Trauma: Injury, Infection & Critical Care, 2011
- The Epidemiology of Vascular Injury in the Wars in Iraq and AfghanistanAnnals of Surgery, 2011
- The concept of damage control: Extending the paradigm to emergency general surgeryInjury, 2008
- The next generation in shock resuscitationThe Lancet, 2004