Overcoming the Hurdle of Fluorescent Compounds in Kinase Screening: A Case Study
- 1 April 2006
- journal article
- Published by SAGE Publications in ASSAY and Drug Development Technologies
- Vol. 4 (2) , 185-196
Abstract
In the field of screening in general and especially in the kinase area, taking into consideration throughput and cost, fluorescence- and luminescence-based assays have been developed as alternatives to radioactivity-based assays. However, fluorescence-based technologies are not devoid of pitfalls. One of the main problems is interference from autofluorescent compounds and the incidence of false-positives as exemplified here with a fluorescence polarization (FP)-based assay. Using the scintillation proximity assay as the in-house standard, we assessed several alternatives to radioactive methods, namely, the amplified luminescent proximity homogeneous assay screen (ALPHAScreen, Perkin-Elmer Life Sciences, Boston, MA), enzyme fragment complementation, FP, and nanofluidics-based fluorescence intensity. Data comparing the sensitivity, robustness, relative sensitivity to autofluorescent compounds, enzyme consumption, and relative costs of each assay for one common kinase are presented. Results obtained seem to favor the nanofluidics mobility shift assay as a method of choice, followed by the direct FP approach, using generic high-molecular-weight phosphate group-binders.Keywords
This publication has 23 references indexed in Scilit:
- Intracellular Signal Transduction Pathway Proteins As Targets for Cancer TherapyJournal of Clinical Oncology, 2005
- Two Simple and Generic Antibody-Independent Kinase Assays: Comparison of a Bioluminescent and a Microfluidic Assay FormatSLAS Discovery, 2004
- Applications of Fluorescent Polymer Superquenching to High Throughput Screening Assays for Protein KinasesASSAY and Drug Development Technologies, 2004
- Miniaturized, Ultra-High Throughput Screening of Tyrosine Kinases Using Homogeneous, Competitive Fluorescence ImmunoassaysASSAY and Drug Development Technologies, 2004
- Evaluation of Compound Interference in Immobilized Metal Ion Affinity-Based Fluorescence Polarization Detection with a Four Million Member Compound CollectionASSAY and Drug Development Technologies, 2003
- High-Throughput Screening with Immobilized Metal Ion Affinity-Based Fluorescence Polarization Detection, A Homogeneous Assay for Protein KinasesASSAY and Drug Development Technologies, 2003
- The specificities of protein kinase inhibitors: an updateBiochemical Journal, 2003
- A High-Throughput, Nonisotopic, Competitive Binding Assay for Kinases Using Nonselective Inhibitor Probes (ED-NSIP™)SLAS Discovery, 2002
- Introduction LANCE™ vs. HTRF® Technologies (or Vice Versa)SLAS Discovery, 1999
- A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening AssaysSLAS Discovery, 1999