Abstract
Background: CoaguChek XS is one of the most widely used point‐of‐care (POC) devices to evaluate prothrombin time for monitoring oral anticoagulant therapy. Unlike laboratory methods, it detects electrical signals produced by thrombin activity to derive the international normalized ratio (INR). Therefore, we hypothesized that laboratory methods and CoaguChek XS could produce different results according to fibrinogen level.Methods: We compared INR values obtained from the CoaguChek XS and conventional laboratory method with 91 plasma samples covering a wide range of fibrinogen levels.Results: The samples were stratified into low, mid, and high fibrinogen groups by fibrinogen levels of 450 mg/dl, respectively. The mean INR difference of the low fibrinogen group was significantly different from that of the mid or high fibrinogen group (P < 0.001). In the low fibrinogen group, CoaguChek XS INR showed a negative bias compared with the laboratory INR, while the mid and high fibrinogen groups had positive bias.Conclusion: Our results suggest that patient selection according to fibrinogen status should precede the implementation of POC testing using CoaguChek XS. Also, periodic comparisons between CoaguChek XS and laboratory INR results should be continued during the use of CoaguChek XS.Keywords
This publication has 24 references indexed in Scilit:
- Self-monitoring and self-management of oral anticoagulation2010
- External quality assessment (EQA) for CoaguChek monitorsThrombosis and Haemostasis, 2010
- Is perioperative point-of-care prothrombin time testing accurate compared to the standard laboratory test?Thrombosis and Haemostasis, 2009
- Internal quality control of prothrombin time in primary care: comparing the use of patient split samples with lyophilised control materialsThrombosis and Haemostasis, 2009
- Point-of-care versus central laboratory coagulation testing during haemorrhagic surgeryThrombosis and Haemostasis, 2009
- Pharmacology and Management of the Vitamin K AntagonistsChest, 2008
- A National Field Study of Quality Assessment of CoaguChek Point-of-Care Testing Prothrombin Time MonitorsAmerican Journal of Clinical Pathology, 2006
- A National Field Study of Quality Assessment of CoaguChek Point-of-Care Testing Prothrombin Time MonitorsAmerican Journal of Clinical Pathology, 2006
- Quality Assessment of CoaguChek Point-of-Care Prothrombin Time Monitors: Comparison of the European Community-Approved Procedure and Conventional External Quality AssessmentClinical Chemistry, 2006
- Patient self‐testing is a reliable and acceptable alternative to laboratory INR monitoringBritish Journal of Haematology, 2004