Flexible 23-channel coil array for high-resolution magnetic resonance imaging at 3 Tesla
Open Access
- 1 November 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0206963
Abstract
The purpose of this work is the design, implementation and evaluation of a mechanically flexible receive-only coil array for magnetic resonance imaging (MRI) at 3 T that can be applied to various target organs and provides high parallel imaging performance. A 23-channel array was designed based on a rigid-flex printed circuit board (PCB). The flexible multi-layer part contains the copper traces forming the coil elements. The rigid part of the PCB houses the solder joints and lumped elements. The coil housing consists of rigid caps mounted above the rigid parts. Adhesive PTFE sheets cover all flexible parts. The developed array was tested on the bench as well as in phantom and in vivo MRI experiments employing parallel imaging acceleration factors up to six. Efficient mutual decoupling between receive elements and detuning between receive array and body coil was achieved. An increased signal-to-noise ratio in comparison to commercial reference coils is demonstrated, especially in regions close to the developed array and for high parallel imaging acceleration factors. Exemplary in vivo images of head, ankle, knee, shoulder and hand are presented. Based on high sensitivity close to the array and low g-factors, this flexible coil is well suited for studies of occipital and temporal cortex, as well as musculoskeletal targets like knee, ankle, elbow and wrist.Keywords
Funding Information
- Österreichische Forschungsförderungsgesellschaft (832107)
- Austrian Science Fund (I1371-B24)
This publication has 25 references indexed in Scilit:
- Size‐optimized 32‐channel brain arrays for 3 T pediatric imagingMagnetic Resonance in Medicine, 2011
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Noise figure limits for circular loop MR coilsMagnetic Resonance in Medicine, 2009
- Mechanically adjustable coil array for wrist MRIMagnetic Resonance in Medicine, 2009
- Comprehensive quantification of signal‐to‐noise ratio and g‐factor for image‐based and k‐space‐based parallel imaging reconstructionsMagnetic Resonance in Medicine, 2008
- Population receptive field estimates in human visual cortexNeuroImage, 2008
- 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometryMagnetic Resonance in Medicine, 2006
- Floating shield current suppression trapConcepts in Magnetic Resonance Part B, 2004
- Design of Matching Networks for Low Noise PreamplifiersMagnetic Resonance in Medicine, 1995
- Quick measurement of NMR-coil sensitivity with a dual-loop probeReview of Scientific Instruments, 1993