Absorbable Sutures in Tendon Repair
Authors:
- 1 August 1995
- journal article
- research article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 20 (4) , 505-508
Abstract
The risks of foreign implantation may be avoided in tendon repair by the use of absorbable sutures, for example polydioxanone. In this study, the in vivo tensile strength half-life of 4/0 polydioxanone was found to be approximately 4 weeks. Using a rabbit model, we compared polydioxanone tendon repairs with polypropylene tendon repairs. Unilateral flexor digitorum longus repairs were performed on 46 rabbits using either polydioxanone or polypropylene. Tendons were harvested at 3 days, 2 weeks and 4 weeks and the tensile breaking strengths were obtained. 30 intact rabbit flexor digitorum longus tendons and 20 freshly repaired tendons were also tested. By 4 weeks, the repair strength had increased eight-fold from approximately 20 N to 166 N. The sutures made little contribution to the overall strength of a 4-week-old repair. There was no significant difference between polydioxanone and polypropylene repairs at any stage. These results show that polydioxanone repairs were as strong as polypropylene during the first critical weeks of tendon healing.Keywords
This publication has 3 references indexed in Scilit:
- An evaluation of suture materials used in tendon surgeryJournal of Hand Surgery (European Volume), 1989
- THE RATE OF HEALING OF TENDONS* AN EXPERIMENTAL STUDY OF TENSILE STRENGTHAnnals of Surgery, 1941
- THE PROCESS OF TENDON REPAIRArchives of Surgery, 1932