Abstract
A mechanics model is developed in this paper for concrete filled steel tubular (CFST) columns subjected to constant axial load and cyclically increasing flexural loading after exposure to ISO-834 standard fire. The predicted cyclic responses for the composite columns are in good agreement with the test results. Based on the theoretical model, parametric analysis was performed on the behaviours of moment ( M) versus curvature ( ϕ) response, and lateral load ( P) versus lateral displacement (Δ) relationship for the composite columns after exposure to fire. Finally, simplified hysteretic models for the moment ( M) versus curvature ( ϕ) response, and the lateral load ( P) versus lateral displacement (Δ) relationship were suggested.Keywords
This publication has 7 references indexed in Scilit:
- Concrete-filled double skin steel tubular (CFDST) beam–columns subjected to cyclic bendingEngineering Structures, 2006
- Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fireJournal of Constructional Steel Research, 2005
- Cyclic performance of concrete-filled steel CHS columns under flexural loadingJournal of Constructional Steel Research, 2005
- Tests on Cyclic Behavior of Concrete-Filled Hollow Structural Steel Columns after Exposure to the ISO-834 Standard FireJournal of Structural Engineering, 2004
- Behavior and calculation on concrete-filled steel CHS (Circular Hollow Section) beam-columnsSteel and Composite Structures, 2004
- Concrete-filled thin-walled steel SHS and RHS beam-columns subjected to cyclic loadingThin-Walled Structures, 2003