Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Authors:
- Jeffrey J. PopmaJPJeffrey J. Popma
- G. Michael DeebGDG. Michael Deeb
- Steven J. YakubovSYSteven J. Yakubov
- Mubashir MumtazMMMubashir Mumtaz
- Hemal GadaHGHemal Gada
- Daniel O’hAirDODaniel O’hAir
- Tanvir BajwaTBTanvir Bajwa
- John C. HeiserJHJohn C. Heiser
- William MerhiWMWilliam Merhi
- Neal S. KleimanNKNeal S. Kleiman
- Judah AskewJAJudah Askew
- Paul SorajjaPSPaul Sorajja
Top Cited Papers
- 2 May 2019
- journal article
- research article
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 380 (18) , 1706-1715
Abstract
Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients’ mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, −1.4 percentage points; 95% Bayesian credible interval for difference, −4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.)Keywords
Funding Information
- Medtronic, Inc
This publication has 21 references indexed in Scilit:
- Outcomes in the Randomized CoreValve US Pivotal High Risk Trial in Patients With a Society of Thoracic Surgeons Risk Score of 7% or LessJAMA Cardiology, 2016
- Neurological Events Following Transcatheter Aortic Valve Replacement and Their PredictorsCirculation: Cardiovascular Interventions, 2016
- The risk and extent of neurologic events are equivalent for high-risk patients treated with transcatheter or surgical aortic valve replacementThe Journal of Thoracic and Cardiovascular Surgery, 2016
- Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for SurgeryCirculation: Cardiovascular Interventions, 2016
- Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve ReplacementCirculation: Cardiovascular Interventions, 2016
- 2-Year Outcomes in Patients Undergoing Surgical or Self-Expanding Transcatheter Aortic Valve ReplacementJACC, 2015
- Transcatheter Aortic Valve Replacement Using a Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis at Extreme Risk for SurgeryJACC, 2014
- The impact of prosthesis–patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-yearsEuropean Heart Journal, 2012
- Monitoring clinical changes in patients with heart failure: A comparison of methodsAmerican Heart Journal, 2005
- Development and evaluation of the Kansas City Cardiomyopathy Questionnaire: a new health status measure for heart failureJACC, 2000