Clinical and economic consequences of non-cardiac incidental findings detected on cardiovascular computed tomography performed prior to transcatheter aortic valve implantation (TAVI)
- 12 June 2015
- journal article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 31 (7) , 1435-1446
Abstract
Transcatheter aortic valve implantation (TAVI) is an effective treatment option for patients with severe degenerative aortic valve stenosis who are high risk for conventional surgery. Computed tomography (CT) performed prior to TAVI can detect pathologies that could influence outcomes following the procedure, however the incidence, cost, and clinical impact of incidental findings has not previously been investigated. 279 patients underwent CT; 188 subsequently had TAVI and 91 were declined. Incidental findings were classified as clinically significant (requiring treatment), indeterminate (requiring further assessment), or clinically insignificant. The primary outcome measure was all-cause mortality up to 3 years. Costs incurred by additional investigations resultant to incidental findings were estimated using the UK Department of Health Payment Tariff. Incidental findings were common in both the TAVI and medical therapy cohorts (54.8 vs. 70.3 %; P = 0.014). Subsequently, 45 extra investigations were recommended for the TAVI cohort, at an overall average cost of £32.69 per TAVI patient. In a univariate model, survival was significantly associated with the presence of a clinically significant or indeterminate finding (HR 1.61; P = 0.021). However, on multivariate analysis outcomes after TAVI were not influenced by any category of incidental finding. Incidental findings are common on CT scans performed prior to TAVI. However, the total cost involved in investigating these findings is low, and incidental findings do not independently identify patients with poorer outcomes after TAVI. The discovery of an incidental finding on CT should not necessarily influence or delay the decision to perform TAVI.Keywords
This publication has 30 references indexed in Scilit:
- Two-year survival of patients screened for transcatheter aortic valve replacement with potentially malignant incidental findings in initial body computed tomographyEuropean Heart Journal - Cardiovascular Imaging, 2015
- The Transcatheter Valve RevolutionCirculation, 2012
- Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesisEuropean Heart Journal, 2012
- Common Incidental Findings on MDCT: Survey of Radiologist Recommendations for Patient ManagementJournal of the American College of Radiology, 2011
- Long-Term Outcomes After Transcatheter Aortic Valve Implantation in High-Risk Patients With Severe Aortic StenosisJACC, 2011
- Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic StenosisCirculation, 2011
- Managing Incidental Findings on Abdominal CT: White Paper of the ACR Incidental Findings CommitteeJournal of the American College of Radiology, 2010
- Cardiac CT: necessary for precise sizing for transcatheter aortic implantation.2010
- Pre-Procedural Imaging of Aortic Root Orientation and DimensionsJACC: Cardiovascular Interventions, 2010
- Guidelines for Management of Small Pulmonary Nodules Detected on CT Scans: A Statement from the Fleischner SocietyRadiology, 2005