Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads
Open Access
- 23 October 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 29 (23) , 2886-2893
Abstract
The aim of the present study was to describe a 10 years single-centre experience in pacing and defibrillating leads removal using an effective and safe modified mechanical dilatation technique. We developed a single mechanical dilating sheath extraction technique with multiple venous entry site approaches. We performed a venous entry site approach (VEA) in cases of exposed leads and an alternative transvenous femoral approach (TFA) combined with an internal transjugular approach (ITA) in the presence of very tight binding sites causing failure of VEA extraction or in cases of free-floating leads. We attempted to remove 2062 leads [1825 pacing and 237 implantable cardiac defibrillating (ICD) leads; 1989 exposed at the venous entry site and 73 free-floating] in 1193 consecutive patients. The VEA was effective in 1799 leads, the TFA in 28, and the ITA in 205; in the overall population, we completely removed 2032 leads (98.4%), partially removed 18 (0.9%), and failed to remove 12 leads (0.6%). Major complications were observed in eight patients (0.7%), causing three deaths (0.3%). Mechanical single sheath extraction technique with multiple venous entry site approaches is effective, safe, and with a good cost effective profile for pacing and ICD leads removal.Keywords
This publication has 30 references indexed in Scilit:
- Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trialEP Europace, 2007
- Usefulness of mechanical transvenous dilation and location of areas of adherence in patients undergoing coronary sinus lead extractionEP Europace, 2007
- Intravascular pacemaker and defibrillator lead extraction: A state-of-the-art reviewHeart Rhythm, 2004
- Nonthoracotomy Implantable Defibrillator Lead Extraction:Pacing and Clinical Electrophysiology, 2003
- Recommendations for Extraction of Chronically Implanted Transvenous Pacing and Defibrillator Leads: Indications, Facilities, TrainingPacing and Clinical Electrophysiology, 2000
- Single Center Experience with Femoral Extraction of Permanent Endocardial Pacing LeadsPacing and Clinical Electrophysiology, 1999
- Complications Associated with Retained Pacemaker LeadsPacing and Clinical Electrophysiology, 1991
- Functionless retained pacing leads in the cardiovascular system. A complication of pacemaker treatment.Heart, 1985
- Complications with retained transvenous pacemaker electrodesAmerican Heart Journal, 1979
- Autopsy Findings with Permanent Pervenous PacemakersCirculation, 1969