Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activitya)
Authors:
- Bin HeBHBin He
- Eric C. FreyEFEric C. Frey
- 29 March 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (4) , 1807-1815
Abstract
Quantitative estimation of in vivo organ uptake is an essential part of treatment planning for targeted radionuclide therapy. This usually involves the use of planar or SPECT scans with acquisition times chosen based more on image quality considerations rather than the minimum needed for precise quantification. In previous simulation studies at clinical count levels (185 MBq 111In), the authors observed larger variations in accuracy of organ activity estimates resulting from anatomical and uptake differences than statistical noise. This suggests that it is possible to reduce the acquisition time without substantially increasing the variation in accuracy. To test this hypothesis, the authors compared the accuracy and variation in accuracy of organ activity estimates obtained from planar and SPECT scans at various count levels. A simulated phantom population with realistic variations in anatomy and biodistribution was used to model variability in a patient population. Planar and SPECT projections were simulated using previously validated Monte Carlo simulation tools. The authors simulated the projections at count levels approximately corresponding to 1.5-30 min of total acquisition time. The projections were processed using previously described quantitative SPECT (QSPECT) and planar (QPlanar) methods. The QSPECT method was based on the OS-EM algorithm with compensations for attenuation, scatter, and collimator-detector response. The QPlanar method is based on the ML-EM algorithm using the same model-based compensation for all the image degrading effects as the QSPECT method. The volumes of interests (VOIs) were defined based on the true organ configuration in the phantoms. The errors in organ activity estimates from different count levels and processing methods were compared in terms of mean and standard deviation over the simulated phantom population. There was little degradation in quantitative reliability when the acquisition time was reduced by half for the QSPECT method (the mean error changed by < 1%, e.g., 0.9%-0.3% = 0.6% for the spleen). The magnitude of the errors and variations in errors for large organ with high uptake were still acceptable for 1.5 min scans, even though the errors were slightly larger than those for the 30 min scans (i.e., < 2% for liver, < 3% for heart). The errors over the ranges of scan times studied for the QPlanar method were all within 0.3% for all organs. These data indicate that, for the purposes of organ activity estimation, acquisition times could be reduced at least by a factor of 2 for the QSPECT and QPlanar methods with little effect on the errors in organ activity estimates. The acquisition time can be further reduced for the QPlanar method, assuming well-registered VOIs are available and the activity distribution in organs can be treated as uniform. Although the differences in accuracy and precision were statistically significant for all the acquisition times shorter than 30 min, the magnitude of the changes in accuracy and precision were small and likely not clinically important. The reduction in SPECT acquisition time justified by this study makes the use of SPECT a more clinically practical alternative to conventional planar scanning for targeted radiotherapy treatment planning.Keywords
Funding Information
- National Institutes of Health (R01-CA109234)
This publication has 30 references indexed in Scilit:
- Comparison Between 2D and 3D Dosimetry Protocols in 90 Y-Ibritumomab Tiuxetan Radioimmunotherapy of Patients with Non-Hodgkin's LymphomaCancer Biotherapy and Radiopharmaceuticals, 2008
- Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agentsPhysics in Medicine & Biology, 2006
- A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECTPhysics in Medicine & Biology, 2005
- Fast modelling of the collimator–detector response in Monte Carlo simulation of SPECT imaging using the angular response functionPhysics in Medicine & Biology, 2005
- Combination of MCNP and SimSET for Monte Carlo simulation of SPECT with medium- and high-energy photonsIEEE Transactions on Nuclear Science, 2002
- Volume reduction versus radiation dose for tumors in previously untreated lymphoma patients who received iodine-131 tositumomab therapyCancer, 2002
- Implementation of a combined X-ray CT-scintillation camera imaging system for localizing and measuring radionuclide uptake: experiments in phantoms and patientsIEEE Transactions on Nuclear Science, 1999
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- A practical method for position-dependent Compton-scatter correction in single photon emission CTIEEE Transactions on Medical Imaging, 1991
- In vivo quantitation of lesion radioactivity using external counting methodsMedical Physics, 1976