Jostent covered stent placement for emergency reconstruction of a ruptured internal carotid artery during or after transsphenoidal surgery
- 1 May 2015
- journal article
- case report
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 122 (5) , 1223-1228
Abstract
OBJECT: Internal carotid artery (ICA) rupture during transsphenoidal surgery (TSS) is an extremely difficult complication to treat. This study aimed to evaluate the immediate and long-term outcomes of covered stent placement for emergency reconstruction of ruptured ICAs during or after TSS. METHODS: Seven patients underwent covered stent placement for emergency reconstruction of a ruptured ICA during or after TSS. The safety and effectiveness of covered stent placement for emergency reconstruction of ruptured ICAs were retrospectively analyzed. RESULTS: Pretreatment angiography showed active bleeding in 6 patients (5 intraoperative and 1 postoperative) and a pseudoaneurysm in 1 patient. Of the 6 patients with active bleeding, 5 were treated with a successive operation to control active bleeding. The other patient was treated just after cardiopulmonary resuscitation due to massive nasal bleeding 20 days after revision of TSS. All active bleeding was controlled immediately after covered stent insertion in these 6 patients. One patient showed a gap between the covered stent and ICA wall without active bleeding 30 minutes after glycoprotein IIb/IIIa inhibitor administration due to in-stent thrombosis. The gap was occluded with coil embolization after completion of the temporarily suspended TSS. The seventh patient, whose ICA tear was treated with surgical suture, underwent covered stent placement for a pseudoaneurysm detected on postoperative Day 2. During a mean follow-up period of 46 months (range 12–85 months), all patients had excellent outcomes (modified Rankin Scale score of 0). All the stented ICAs were patent on vascular imaging follow-up at a mean of 34 months (range 12–85 months). CONCLUSIONS: Covered stents appear to be a safe and effective option for emergency reconstruction of ruptured ICAs during or after TSS.Keywords
This publication has 16 references indexed in Scilit:
- Endovascular Treatment of Posttraumatic Carotid‐Cavernous Fistulas and Pseudoaneurysms with Covered StentsJournal of Neuroimaging, 2013
- Covered coronary stent grafts as a treatment option for carotid-cavernous fistulas: Our initial experienceNeurology India, 2011
- Traumatic Carotid-Cavernous Fistulas Treated with Covered Stents: Experience of 12 CasesWorld Neurosurgery, 2010
- Emergency endovascular Stent graft and coil placement for internal carotid artery injury during transsphenoidal surgerySurgical Neurology, 2009
- The use of a covered stent graft for obliteration of high-flow carotid cavernous fistula presenting with life-threatening epistaxisJournal of NeuroInterventional Surgery, 2009
- Treatment of Carotid Cavernous Fistulas Using Covered Stents: Midterm Results in Seven PatientsAmerican Journal of Neuroradiology, 2007
- Emergency placement of a self-expandable covered stent for carotid artery injury during trans-sphenoidal surgeryBritish Journal Of Neurosurgery, 2006
- Vascular Injury and Transsphenoidal Surgery2006
- Complications of Transsphenoidal Surgery: Results of a National Survey, Review of the Literature, and Personal ExperienceNeurosurgery, 1997
- False aneurysm of the cavernous carotid artery and progressive external ophthalmoplegia after transsphenoidal hypophysectomyJournal of Neurosurgery, 1979