Slender High-Strength Concrete Columns Subjected to Eccentric Loading
Authors:
- 1 March 1998
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 124 (3) , 233-240
Abstract
An experimental study of the behavior of reinforced concrete columns and results of a nonlinear finite-element analysis are presented. Twelve full-scale columns with square sections were tested under eccentric monotonic loading. Effects of key parameters such as concrete strength, stirrup spacing, slenderness of the columns, and eccentricity of the applied axial load were studied. Significant gains in load capacity were obtained with increased concrete strength. The results of the finite-element analysis correlate well with the results of the tests. A parametric study was made to examine the difference in failure modes for the different concrete strengths, length-to-width ratios, and loading eccentricities. The higher compressive concrete strength was especially advantageous when the load eccentricity was small. When the eccentricity was increased, the strength of the high-strength concrete columns decreased more rapidly than that of the normal-strength columns. However, the high-strength concrete columns...Keywords
This publication has 4 references indexed in Scilit:
- High‐Strength Concrete Columns Confined by Rectangular TiesJournal of Structural Engineering, 1994
- Strength and Ductility of Confined ConcreteJournal of Structural Engineering, 1992
- Slenderness effects in high-strength concrete columnsCanadian Journal of Civil Engineering, 1991
- Observed Stress‐Strain Behavior of Confined ConcreteJournal of Structural Engineering, 1988