The effects of target size and tissue density on the minimum margin required for random errors
Authors:
- Marnix G. WitteMWMarnix G. Witte
- Joris van der GeerJGJoris van der Geer
- Christoph SchneiderCSChristoph Schneider
- Joos V. LebesqueJLJoos V. Lebesque
- Marcel van HerkMHMarcel van Herk
- 28 October 2004
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (11) , 3068-3079
Abstract
The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of the prescribed dose for 90% of the patients. The dose distribution model incorporated two Gaussians, and could accurately represent realistic dose profiles for various target sizes in lung and water. It was found that variations in target size and tissue density lead to significant changes in the minimum margin required for random errors. The random error margin increased with tissue density, and decreased with target size. The required margins were similar for dose distributions of spherical and cylindrical symmetry. Significant dose outside the spherical high dose region, as could result from multiple incident beams, lead to an increased margin for the larger targets. We could confirm that the previously proposed margin of 0.7 times the standard deviation of the random errors is safe for standard deviations up to 5 mm, except for very small targets in dense materiaKeywords
This publication has 22 references indexed in Scilit:
- A general methodology for three‐dimensional analysis of variation in target volume delineationMedical Physics, 1999
- Set-up variation of patients treated with radiotherapy to the prostate measured with an electronic portal imaging deviceAustralasian Radiology, 1998
- Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997
- Current Clinical Practice Versus New Developments in Target Volume and Dose Specification Procedures: A Contradiction?Acta Oncologica, 1997
- Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registrationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Measurement of prostate movement over the course of routine radiotherapy using implanted markersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- The effect of setup uncertainties on the treatment of nasopharynx cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Alpha/beta value and the importance of size of dose per fraction for late complications in the supraglottic larynxRadiotherapy and Oncology, 1986