Abstract
Purpose Atrial fibrillation (AF) is the most common cardiac dysrhythmia. Appropriate detection of AF and early initiation of oral anticoagulation therapy are critical to reduce the risk of stroke. Patients with implantable cardioverter defibrillators (ICD) are at high risk of developing AF. The purpose of the Dx-AF study is to demonstrate that a novel single-lead VDD-ICD system (Linox smart S DX) will facilitate adequate recognition of sub-clinical AF and ultimately stroke prevention with a comparable safety profile in comparison to VVI-ICD. Methods and results Dx-AF is a prospective, randomized controlled, open-label trial. Patients who are indicated to receive a single-chamber ICD will be randomized to a VDD-ICD (experimental group) or single-chamber ICD (control group). We have used a sample size of 355, which after generous allowance for loss-to-follow-up, yields a sample size of 378 patients at up to 13 Canadian sites. The trial will enroll patients with ischemic or non-ischemic cardiomyopathy, age > 50 years, LVEF < 50%, scheduled for primary or secondary prevention single-chamber ICD, with no ECG-documented history of AF or flutter. The primary (efficacy) outcome of this study will be the time to the first detected and confirmed episode of AF or atrial flutter lasting at least 6 min. The secondary (safety) outcome will be a composite outcome of serious device-related complications. The proposed follow-up period in this trial will be 36 months after randomization. Conclusions The Dx-AF Study should provide significant scientific evidence and guidance to an adequate ICD system choice and early AF detection/management hence improve clinical outcomes in a large patient population.Keywords
Funding Information
- Biotronik
This publication has 37 references indexed in Scilit:
- Probing oral anticoagulation in patients with atrial high rate episodes: Rationale and design of the Non–vitamin K antagonist Oral anticoagulants in patients with Atrial High rate episodes (NOAH–AFNET 6) trialAmerican Heart Journal, 2017
- Rationale and design of the Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation (ARTESiA) trialAmerican Heart Journal, 2017
- Real-world performance of an enhanced atrial fibrillation detection algorithm in an insertable cardiac monitorHeart Rhythm, 2016
- EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoringEuropean Heart Journal, 2014
- Clinical significance of atrial fibrillation detected by cardiac implantable electronic devicesHeart Rhythm, 2014
- Association of Single- vs Dual-Chamber ICDs With Mortality, Readmissions, and Complications Among Patients Receiving an ICD for Primary PreventionJAMA, 2013
- Comparison of β-Blockers, Amiodarone Plus β-Blockers, or Sotalol for Prevention of Shocks From Implantable Cardioverter DefibrillatorsThe OPTIC Study: A Randomized TrialJAMA, 2006
- Chronic Experiences with a Single Lead Dual Chamber Implantable Cardioverter Defibrillator SystemPacing and Clinical Electrophysiology, 2003
- Atrial fibrillation is associated with an increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular systolic dysfunction: a retrospective analysis of the SOLVD trialsJACC, 1998
- Sextapolar catheter electrode for temporary sequential atrioventricular pacingCardiovascular Research, 1974