A Low Component Count Series Voltage Compensation Scheme for DFIG WTs to Enhance Fault Ride-Through Capability
Authors:
- 16 September 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 30 (1) , 208-217
Abstract
Fault ride-through (FRT) operation has been a challenge for the doubly fed induction generator (DFIG) based wind turbines (WTs) as the stator winding is directly connected to the grid. Additionally, several grid codes have been established for the grid interconnection of WTs, which demand the WT to stay connected and provide the predefined reactive current support to the grid during FRT operation. The series voltage compensation (SeVC) based FRT schemes for DFIG WTs outperforms all others in terms of smooth transient performance. However, such FRT schemes require an additional voltage-source converter (VSC) and a bulkier series transformer to provide the SeVC. This paper proposes a low component count SeVC scheme that is applicable to both individual WTs and wind parks to cope up with the recent grid codes requirements. The proposed configuration eliminates the need of a series transformer and an additional VSC for the SeVC operation with the use of three additional IGBTs/switches. Furthermore, a coordinated control strategy is proposed to control the WT that enhance its FRT capabilities. The proposed low component count FRT scheme and coordinated control strategy are validated using the detailed mathematical modeling and simulation of 1.5 MW DFIG WT.Keywords
This publication has 23 references indexed in Scilit:
- A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage RestorersIEEE Transactions on Energy Conversion, 2011
- Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid FaultsIEEE Transactions on Power Electronics, 2011
- Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage RestorersIEEE Transactions on Energy Conversion, 2011
- Series Voltage Compensation for DFIG Wind Turbine Low-Voltage Ride-Through SolutionIEEE Transactions on Energy Conversion, 2011
- Decoupled-DFIG Fault Ride-Through Strategy for Enhanced Stability Performance During Grid FaultsIEEE Transactions on Sustainable Energy, 2010
- A Series-Dynamic-Resistor-Based Converter Protection Scheme for Doubly-Fed Induction Generator During Various Fault ConditionsIEEE Transactions on Energy Conversion, 2010
- Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage DipsIEEE Transactions on Energy Conversion, 2007
- Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors (March 2007)IEEE Transactions on Power Systems, 2007
- Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network DisturbanceIEEE Transactions on Power Systems, 2006
- Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage DipIEEE Transactions on Energy Conversion, 2005