Monitoring hypnotic effect and nociception with two EEG-derived indices, qCON and qNOX, during general anaesthesia
- 4 July 2014
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 58 (8) , 933-941
Abstract
The objective of the present study was to validate the qCON index of hypnotic effect and the qNOX index of nociception. Both indices are derived from the frontal electroencephalogram (EEG) and implemented in the qCON 2000 monitor (Quantium Medical, Barcelona, Spain). The study was approved by the local ethics committee, including data from 60 patients scheduled for ambulatory surgery undergoing general anaesthesia with propofol and remifentanil, using TCI. The Bis (Covidien, Boulder, CO, USA) was recorded simultaneously with the qCON. Loss of eyelash reflex [loss of consciousness (LOC)] was recorded, and prediction probability for Bis and qCON was calculated. Movement as a response to noxious stimulation [laryngeal mask airway (LMA) insertion, laryngoscopy and tracheal intubation] was registered. The correlation coefficient between qCON and Bis was calculated. The patients were divided into movers/non-movers as a response to noxious stimulation. A paired t-test was used to assess significant difference for qCON and qNOX for movers/non-movers. The prediction probability (Pk) and the standard error (SE) for qCON and Bis for detecting LOC was 0.92 (0.02) and 0.94 (0.02) respectively (t-test, no significant difference). The R between qCON and Bis was 0.85. During the general anaesthesia (Ce propofol > 2 μg/ml, Ce remifentanil > 2 ng/ml), the mean value and standard deviation (SD) for qCON was 45 (8), while for qNOX it was 40 (6). The qNOX pre-stimuli values were significantly different (P < 0.05) for movers/non-movers as a response to LMA insertion [62.5 (24.0) vs. 45.5 (24.1)], tracheal intubation [58.7 (21.8) vs. 41.4 (20.9)], laryngoscopy [54.1 (21.4) vs. 41.0 (20.8)]. There were no significant differences in remifentanil or propofol effect-site concentrations for movers vs. non-movers. The qCON was able to reliably detect LOC during general anaesthesia with propofol and remifentanil. The qNOX showed significant overlap between movers and non-movers, but it was able to predict whether or not the patient would move as a response to noxious stimulation, although the anaesthetic concentrations were similar.Keywords
Funding Information
- Fondo de Investigaciones Sanitarias, Health Department, Government of Spain (PI/050072)
This publication has 28 references indexed in Scilit:
- Monitoring the nociception level: a multi-parameter approachJournal of Clinical Monitoring and Computing, 2013
- Modeling the Influence of the A118G Polymorphism in the OPRM1 Gene and of Noxious Stimulation on the Synergistic Relation between Propofol and RemifentanilAnesthesiology, 2013
- Prospective observational study of the non-invasive assessment of immediate postoperative pain using the analgesia/nociception index (ANI)British Journal of Anaesthesia, 2013
- Modeling the Effect of Propofol and Remifentanil Combinations for Sedation-Analgesia in Endoscopic Procedures Using an Adaptive Neuro Fuzzy Inference System (ANFIS)Anesthesia & Analgesia, 2011
- Changes in skin conductance as a tool to monitor nociceptive stimulation and painCurrent Opinion in Anaesthesiology, 2008
- Variability Comparison of the Composite Auditory Evoked Potential Index and the Bispectral Index During Propofol-Fentanyl AnesthesiaAnesthesia & Analgesia, 2008
- Cerebral State Index during Propofol AnesthesiaAnesthesiology, 2006
- Spectral Entropy Monitoring Is Associated with Reduced Propofol Use and Faster Emergence in Propofol–Nitrous Oxide–Alfentanil AnesthesiaAnesthesiology, 2005
- Peroperative depth of anaesthesia may influence postoperative opioid requirementsActa Anaesthesiologica Scandinavica, 2005
- Neuromonitoring for awareness during surgeryThe Lancet, 2004