Determination of the Optimum Removal Efficiency of Fine Particulate Matter Using Activated Carbon Fiber (ACF)
Open Access
- 7 November 2020
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (21) , 8230
Abstract
In Korea, concentrations of particulate matter (PM10) are significantly higher in urban railway tunnels (178.1 μg/m3) than in metropolitan areas (49 μg/m3). In railway tunnels in Korea, it was maintained at 3–4 times higher concentration than general atmosphere and platform. Dust generated by trains is scattered at high speed in these tunnels, making filtration difficult; therefore, the development of filters that can be maintained in tunnels is required. In the present study, we examined PM adsorption in the laboratory scale using activated carbon fiber (ACF), which has high adsorption and capacity. The ACF depth, velocity of flow, and fine PM concentration in the tunnel were the experimental variables. We compared PM concentrations before and after the filter experiments, and calculated removal efficiency to determine the optimal conditions. Comprehensive examination of the experimental variables and differential pressure showed that the optimal conditions for an ACF specimen were a wind speed of 3.0 m/s and the ACF depth of 400 mm. The average removal efficiency of PM10 was 55.5%, and that of PM2.5 was 36.6%. The reproducibility tests showed that the ACF filter could be washed and reused and is suitable for various places because it is easily maintained.Keywords
Funding Information
- This work was supported by a grant from the Subway Fine Dust Reduction Technology Development Project of the Ministry of Land Infrastructure and Transport (20QPPW-B152306-02)
This publication has 11 references indexed in Scilit:
- Estimating the Reduction Amount of the High Level Particulate Matter Concentrations, Caused by External Transport, by Operating Air Cleaning Tower Buildings or Cleaning Devices Installed on Vehicles in Urban Ambient AirJournal of Korean Society for Atmospheric Environment, 2019
- Characteristics of Particulate Matter Concentration and Classification of Contamination Patterns in the Seoul Metropolitan Subway TunnelsJournal of Korean Society for Atmospheric Environment, 2017
- Carbon nanotubes / activated carbon fiber based air filter media for simultaneous removal of particulate matter and ozoneBuilding and Environment, 2017
- Performance of activated carbon-impregnated cellulose filters for indoor VOCs and dust controlInternational Journal of Environmental Science and Technology, 2016
- A review on the human health impact of airborne particulate matterEnvironment International, 2015
- High secondary aerosol contribution to particulate pollution during haze events in ChinaNature, 2014
- The Effect of Fine and Coarse Particulate Air Pollution on Mortality: A National AnalysisEnvironmental Health Perspectives, 2009
- Reaction of NO with urea supported on activated carbonsApplied Catalysis B: Environment and Energy, 2005
- Indoor air purification by photocatalyst TiO2 immobilized on an activated carbon filter installed in an air cleanerChemical Engineering Science, 2005
- Removal of volatile organic compound by activated carbon fiberCarbon, 2004