Activated sludge model 2d calibration with full-scale WWTP data: comparing model parameter identifiability with influent and operational uncertainty
Open Access
- 13 December 2013
- journal article
- research article
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 37 (7) , 1271-1287
Abstract
The present work developed a model for the description of a full-scale wastewater treatment plant (WWTP) (Manresa, Catalonia, Spain) for further plant upgrades based on the systematic parameter calibration of the activated sludge model 2d (ASM2d) using a methodology based on the Fisher information matrix. The influent was characterized for the application of the ASM2d and the confidence interval of the calibrated parameters was also assessed. No expert knowledge was necessary for model calibration and a huge available plant database was converted into more useful information. The effect of the influent and operating variables on the model fit was also studied using these variables as calibrating parameters and keeping the ASM2d kinetic and stoichiometric parameters, which traditionally are the calibration parameters, at their default values. Such an “inversion” of the traditional way of model fitting allowed evaluating the sensitivity of the main model outputs regarding the influent and the operating variables changes. This new approach is able to evaluate the capacity of the operational variables used by the WWTP feedback control loops to overcome external disturbances in the influent and kinetic/stoichiometric model parameters uncertainties. In addition, the study of the influence of operating variables on the model outputs provides useful information to select input and output variables in decentralized control structures.Keywords
This publication has 29 references indexed in Scilit:
- A practical protocol for calibration of nutrient removal wastewater treatment modelsJournal of Hydroinformatics, 2011
- Systematic identifiability study based on the Fisher Information Matrix for reducing the number of parameters calibration of an activated sludge modelEnvironmental Modelling & Software, 2009
- Wastewater treatment modelling: dealing with uncertaintiesWater Science & Technology, 2009
- Uncertainty analysis in WWTP model applications: A critical discussion using an example from designWater Research, 2009
- Parameter subset selection for the dynamic calibration of activated sludge models (ASMs): experience versus systems analysisWater Science & Technology, 2007
- Modelling and control strategy testing of biological and chemical phosphorus removal at Avedøre WWTPWater Science & Technology, 2006
- Instrumentation, control and automation in the water industry – state-of-the-art and new challengesWater Science & Technology, 2006
- Improvement of ammonia removal in activated sludge process with feedforward-feedback aeration controllersWater Science & Technology, 2006
- A critical comparison of systematic calibration protocols for activated sludge models: A SWOT analysisWater Research, 2005
- Reducing the size of a nitrogen removal activated sludge plant by shortening the retention time of inert solids via sludge storageWater Research, 2000