A Novel Multi-Dimensional Composition Method Based on Time Series Similarity for Array Pulse Wave Signals Detecting
Open Access
- 14 November 2020
- journal article
- research article
- Published by MDPI AG in Algorithms
- Vol. 13 (11) , 297
Abstract
Pulse wave signal sensed over the radial artery on the wrist is a crucial physiological indicator in disease diagnosis. The sensor array composed of multiple sensors has the ability to collect abundant pulse wave information. As a result, it has gradually attracted the attention of practitioners. However, few practical methods are used to obtain a one-dimensional pulse wave from the sensor array’s spatial multi-dimensional signals. The current algorithm using pulse wave with the highest amplitude value as the significant data suffers from low consistency because the signal acquired each time differs significantly due to the sensor’s relative position shift to the test area. This paper proposes a processing method based on time series similarity, which can take full advantage of sensor arrays’ spatial multi-dimensional characteristics and effectively avoid the above factors’ influence. A pulse wave acquisition system (PWAS) containing a micro-electro-mechanical system (MEMS) sensor array is continuously extruded using a stable dynamic pressure input source to simulate the pulse wave acquisition process. Experiments are conducted at multiple test locations with multiple data acquisitions to evaluate the performance of the algorithm. The experimental results show that the newly proposed processing method using time series similarity as the criterion has better consistency and stability.Keywords
Funding Information
- the National Science and Technology Major Project (No. 2018ZX01031201)
- the National Key Research and Development Program (No. 2018YFC2001100)
- Key Program of the Chinese Academy of Sciences (No. KFZD-SW-218)
This publication has 34 references indexed in Scilit:
- Effects of parameters on the accuracy and precision of ultrasound-based local pulse wave velocity measurement: a simulation studyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- A Compound Pressure Signal Acquisition System for Multichannel Wrist Pulse Signal AnalysisIEEE Transactions on Instrumentation and Measurement, 2014
- How to standardize the pulse-taking method of traditional Chinese medicine pulse diagnosisComputers in Biology and Medicine, 2013
- An Innovative Piezoelectric-Based Method for Measuring Pulse Wave Velocity in Patients With HypertensionThe Journal of Clinical Hypertension, 2011
- Comparative Cytogenetics Analysis of Chlamys farreri, Patinopecten yessoensis, and Argopecten irradians with C0t‐1 DNA by Fluorescence In Situ HybridizationEvidence-Based Complementary and Alternative Medicine, 2011
- Quantitative Assessment of Arterial Wall Biomechanical Properties Using Shear Wave ImagingUltrasound in Medicine & Biology, 2010
- A piezo-film-based measurement system for global haemodynamic assessmentPhysiological Measurement, 2010
- Urgent Problems of Metrological Assurance of Optical Pulse OximetryIEEE Transactions on Instrumentation and Measurement, 2006
- Aortic Pulse-Wave Velocity and Its Relationship to Mortality in Diabetes and Glucose IntoleranceCirculation, 2002
- Cubic convolution interpolation for digital image processingIEEE Transactions on Acoustics, Speech, and Signal Processing, 1981