Achievable dose reductions with gonadal shielding for children and adults during abdominal/pelvic radiographic examinations: A Monte Carlo simulation
- 27 September 2020
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 47 (11) , 5514-5522
Abstract
Purpose Recently, medical professionals have reconsidered the practice of routine gonadal shielding for radiographic examinations. The objective of this study was to evaluate the gonadal dose reduction achievable with gonadal shields in the primary beam during abdominal/pelvic radiographic examinations under ideal and non‐ideal shielding placement. Methods CT scans of CIRS anthropomorphic phantoms were used to perform voxelized Monte Carlo simulations of the photon transport during abdominal/pelvic radiographic examinations with standard filtration and 0.1 mm Cu + 1 mm Al added filtration to estimate gonadal doses for an adult, 5 year old, and newborn phantom with and without gonadal shields. The reduction in dose when the shields were not placed at the ideal locations was also evaluated. The ratio of the number of scattered‐to‐primary photons (SPR) across the anteroposterior (AP) dimension of the phantoms was also reported. Results The simulated dose reduction with ideal shielding placement for the testes and ovaries ranged from 80% to 90% and 55% to 70%, respectively. For children, a misalignment of the shield to the gonad of 4 cm reduced the measured dose reduction to the gonads to <10%. For adults, this effect did not occur until the misalignment increased to ~6 cm. Effects of dose reduction with and without the gonadal shields properly placed were similar for standard filtration and added filtration. SPR at the level of the testes was consistently < 1 for all phantoms. SPR for ovaries was ~1.5 for the adult and 5‐yr old, and ~1 for the newborn phantom Conclusion Dose reduction with ideal alignment of the simulated gonadal shield to the gonads in this study was greater for the testes than the ovaries; both reductions were substantial. However, the dose reductions were greatly reduced (to < 10%) for both sexes with misalignment of the gonads to the shields by 4 cm for children and 6 cm for adults.Keywords
This publication has 27 references indexed in Scilit:
- More harm than good? The anatomy of misguided shielding of the ovariesBritish Journal of Radiology, 2012
- Testicular volumes revisited: A proposal for a simple clinical method that can closely match the volumes obtained by ultrasound and its clinical applicationInternational Journal of Pediatric Endocrinology, 2012
- Establishing a standard calibration methodology for MOSFET detectors in computed tomography dosimetryMedical Physics, 2012
- Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefitInsights into Imaging, 2011
- AbstractAnnals of the ICRP, 2007
- US of the Pediatric Female Pelvis: A Clinical PerspectiveRadioGraphics, 2001
- AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiologyMedical Physics, 2001
- Ovarian Volume Related to AgeGynecologic Oncology, 2000
- Gonadal Protection from X radiation for the FemaleBritish Journal of Radiology, 1958
- Protection of the Male Gonads in Diagnostic ProceduresBritish Journal of Radiology, 1957