Quantitative and Qualitative Assessment of Yttrium-90 PET/CT Imaging
Authors:
Open Access
- 4 November 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e110401
Abstract
Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with 90Y labeled microspheres. The aim of this work was to image and quantify 90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10–37 mm ∅) was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany) with time-of-flight (TOF) acquisition. A sphere to background ratio of 8∶1, with a total 90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d). he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. mages were reconstructed with 3D ordered subset expectation maximization (OSEM) and point spread function (PSF) for iteration numbers of 1–12 with 21 (TOF) and 24 (non-TOF) subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI) analysis of the background (100 voxels), spheres (4 voxels) and the central low density insert (25 voxels). For the largest sphere, the recovery coefficient (RC) values for the 30 min –2-bed position, 30 min-single bed and 120 min-single bed were 1.12±0.20, 1.14±0.13, 0.97±0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion.Keywords
This publication has 38 references indexed in Scilit:
- Is the Image Quality of I-124-PET Impaired by an Automatic Correction of Prompt Gammas?PLOS ONE, 2013
- Boosted selective internal radiation therapy with 90Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising conceptEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- Emission of β+ Particles Via Internal Pair Production in the 0+ – 0+ Transition of 90Zr: Historical Background and Current Applications in Nuclear Medicine ImagingAtoms, 2013
- Quantitative Comparison of PET and Bremsstrahlung SPECT for Imaging the In Vivo Yttrium-90 Microsphere Distribution after Liver RadioembolizationPLOS ONE, 2013
- Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheresEJNMMI Research, 2013
- Post-radioembolization yttrium-90 PET/CT - part 1: diagnostic reportingEJNMMI Research, 2013
- Assessment of acquisition protocols for routine imaging of Y-90 using PET/CTEJNMMI Research, 2013
- Quantitative Evaluation of Scintillation Camera Imaging Characteristics of Isotopes Used in Liver RadioembolizationPLOS ONE, 2011
- Selective intraarterial radionuclide therapy with Yttrium-90 (Y-90) microspheres for unresectable primary and metastatic liver tumorsWorld Journal of Surgical Oncology, 2011
- Selective internal radiation therapy (SIRT): a new modality for treating patients with colorectal liver metastasesHPB, 2004