A 0.5 V 68 nW ECG Monitoring Analog Front-End for Arrhythmia Diagnosis
Open Access
- 17 August 2018
- journal article
- research article
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 8 (3) , 27
Abstract
This paper presents a power efficient analog front-end (AFE) for electrocardiogram (ECG) signal monitoring and arrhythmia diagnosis. The AFE uses low-noise and low-power circuit design methodologies and aggressive voltage scaling to satisfy both the low power consumption and low input-referred noise requirements of ECG signal acquisition systems. The AFE was realized with a three-stage fully differential AC-coupled amplifier, and it provides bio-signal acquisition with programmable gain and bandwidth. The AFE was implemented in a 130 nm CMOS process, and it has a measured tunable mid-band gain from 31 to 52 dB with tunable low-pass and high-pass corner frequencies. Under only 0.5 V supply voltage, it consumes 68 nW of power with an input-referred noise of 2.8 µVrms and a power efficiency factor (PEF) of 3.9, which makes it very suitable for energy-harvesting applications. The low-noise 68nW AFE was also integrated on a self-powered physiological monitoring System on Chip (SoC) that is used to capture ECG bio-signals. Heart rate extraction (R-R) detection algorithms were implemented and utilized to analyze the ECG data received by the AFE, showing the feasibility of <100 nW AFE for continuous ECG monitoring applications.Keywords
Funding Information
- National Science Foundation NERC ASSIST Center (EEC-1160483)
This publication has 21 references indexed in Scilit:
- An Analog Front-End for a Multifunction Sensor Employing a Weak-Inversion Biasing Technique With 26 nVrms, 25 aCrms, and 19 fArms Input-Referred NoiseIEEE Journal of Solid-State Circuits, 2016
- Characterization of Human Body-Based Thermal and Vibration Energy Harvesting for Wearable DevicesIEEE Journal on Emerging and Selected Topics in Circuits and Systems, 2014
- A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency FactorIEEE Transactions on Biomedical Circuits and Systems, 2013
- An Orthogonal Current-Reuse Amplifier for Multi-Channel SensingIEEE Journal of Solid-State Circuits, 2013
- A Batteryless 19 $\mu$W MICS/ISM-Band Energy Harvesting Body Sensor Node SoC for ExG ApplicationsIEEE Journal of Solid-State Circuits, 2013
- An 8-Channel Scalable EEG Acquisition SoC With Patient-Specific Seizure Classification and Recording ProcessorIEEE Journal of Solid-State Circuits, 2012
- A 0.013 ${\hbox {mm}}^{2}$, 5 $\mu\hbox{W}$, DC-Coupled Neural Signal Acquisition IC With 0.5 V SupplyIEEE Journal of Solid-State Circuits, 2011
- A Biomedical Sensor Interface With a sinc Filter and Interference CancellationIEEE Journal of Solid-State Circuits, 2011
- A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal MonitoringIEEE Journal of Solid-State Circuits, 2010
- A low-power low-noise cmos for amplifier neural recording applicationsIEEE Journal of Solid-State Circuits, 2003