Long-term outcomes of two types of metal stent for chronic benign ureteral strictures
Open Access
- 6 May 2019
- journal article
- research article
- Published by Springer Nature in BMC Urology
- Vol. 19 (1) , 1-8
Abstract
We aimed to compare the results of long-term use of two types of metal stent for chronic benign ureteral strictures. Our study included 46 ureter units (UUs) that underwent metal stent placement from 2010 to 2017. We included benign ureteral strictures causes by variety reasons that could not be solved by other treatment and malignant obstructions were excluded. Covered mesh stent (Uventa™) and a thermo-expandable stent (Memokath 051™) were used. Primary success was defined as maintaining patency without procedures and overall success was defined as maintaining patency with additional procedures. We placed covered mesh stents in 25 UUs and thermo-expandable stents in 21 UUs. The mean follow-up duration of each stent was 41.4 ± 23.1 and 34.4 ± 16.5 months (p = 0.250). In the first year of stent insertion, primary success was achieved in 54.9 and 70.4% (p = 0.204). Overall success was achieved in 78.7 and 75.4% in same duration, respectively (p = 0.586). Longer stent placement had positive predictive value on both success rates (HR = 0.185, p = 0.047 and HR = 0.111, p = 0.018). Prior radiation therapy and non-pelvic ureter stricture both adversely affected the overall success rate (HR = 5.412, p = 0.048 and HR = 4.203, p = 0.030). Previous PCN status had negative predictive value for both success rates (HR = 4.014, p = 0.003 and HR = 3.064, p = 0.035). The treatment outcomes of two types of metal stent were comparable, especially in the first year of stent insertion.Keywords
Funding Information
- National Research Foundation of Korea (2017R1E1A1A01077487)
This publication has 21 references indexed in Scilit:
- Complications After Polymeric and Metallic Ureteral Stent Placements Including Three Types of FistulaJournal of Endourology, 2015
- Comparison of Efficacy and Safety Between a Segmental Thermo-expandable Metal Alloy Spiral Stent (Memokath 051) and a Self-Expandable Covered Metallic Stent (UVENTA) in the Management of Ureteral ObstructionsJournal of Laparoendoscopic & Advanced Surgical Techniques, 2014
- A Single-Institution Experience with Metallic Ureteral Stents: A Cost-Effective Method of Managing Deficiencies in Ureteral DrainageInternational braz j urol, 2014
- Efficacy and Safety of a Novel, Double-Layered, Coated, Self-Expandable Metallic Mesh Stent (Uventa ™ ) in Malignant Ureteral ObstructionsJournal of Endourology, 2013
- Application of resonance metallic stents for ureteral obstructionBJU International, 2010
- Current status of metal stents for managing malignant ureteric obstructionBJU International, 2010
- Metallic Ureteral Stents: A Cost-Effective Method of Managing Benign Upper Tract ObstructionJournal of Endourology, 2010
- Ureteric response to abdominal radiotherapy and metallic double‐pigtail ureteric stents: a pig modelBJU International, 2009
- Externally Coated Ureteral Metallic Stents: An Unfavorable Clinical ExperienceEuropean Urology, 2002
- A NEW TREATMENT FOR URETHRAL STRICTURESThe Lancet, 1988