Wideband digital phase comparator for high current shunts
Preprint
Abstract
A wideband phase comparator for precise measurements of phase difference of high current shunts has been developed at INRIM. The two-input digital phase detector is realized with a precision wideband digitizer connected through a pair of symmetric active guarded transformers to the outputs of the shunts under comparison. Data are first acquired asynchronously, and then transferred from on-board memory to host memory. Because of the large amount of data collected the filtering process and the analysis algorithms are performed outside the acquisition routine. Most of the systematic errors can be compensated by a proper inversion procedure. The system is suitable for comparing shunts in a wide range of currents, from several hundred of milliampere up to 100 A, and frequencies ranging between 500 Hz and 100 kHz. Expanded uncertainty (k=2) less than 0.05 mrad, for frequency up to 100 kHz, is obtained in the measurement of the phase difference of a group of 10 A shunts, provided by some European NMIs, using a digitizer with sampling frequency up to 1 MHz. An enhanced version of the phase comparator employs a new digital phase detector with higher sampling frequency and vertical resolution. This permits to decrease the contribution to the uncertainty budget of the phase detector of a factor two from 20 kHz to 100 kHz. Theories and experiments show that the phase difference between two high precision wideband digitizers, coupled as phase detector, depends on multiple factors derived from both analog and digital imprint of each sampling system.Keywords
All Related Versions
- Version 1, 2011-10-05, ArXiv
- Published version: Metrologia, 49 (3), 349.
This publication has 12 references indexed in Scilit:
- Dual Transformer for Power Measurements in the Audio-Frequency BandIEEE Transactions on Instrumentation and Measurement, 2010
- Coaxial Shunts as AC–DC Transfer Standards of CurrentIEEE Transactions on Instrumentation and Measurement, 2008
- Direct Measurement of AC Current by Measuring the Voltage Drop on the Coaxial Current ShuntIEEE Transactions on Instrumentation and Measurement, 2008
- Design, Modeling, and Verification of High-Performance AC–DC Current Shunts From Inexpensive ComponentsIEEE Transactions on Instrumentation and Measurement, 2007
- Measurement of Phase Angle Errors of Precision Current Shunts in the Frequency Range From 40 Hz to 200 kHzIEEE Transactions on Instrumentation and Measurement, 2007
- Use of integrative analog-to-digital converters for high-precision measurement of electrical powerIEEE Transactions on Instrumentation and Measurement, 2001
- The traceability for the AC-DC transfer standard: an overview of the activity at the IENMeasurement, 1997
- Standards for AC-DC TransferMetrologia, 1992
- Balanced transconductance amplifier for precision comparison of AC/DC thermal current convertorsIEE Proceedings A Science, Measurement and Technology, 1992
- AC-DC difference relationships for current shunt and thermal converter combinationsIEEE Transactions on Instrumentation and Measurement, 1991