Joint 2D–3D cross-pseudo supervision for carotid vessel wall segmentation
Open Access
- 17 November 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1203400
Abstract
Introduction: The segmentation of the carotid vessel wall using black-blood magnetic resonance images was a crucial step in the diagnosis of atherosclerosis. The objective was to accurately isolate the region between the artery lumen and outer wall. Although supervised learning methods achieved remarkable accuracy in vessel segmentation, their effectiveness remained limited due to their reliance on extensive labeled data and human intervention. Furthermore, when confronted with three-dimensional datasets featuring insufficient and discontinuous label data, these learning-based approaches could lose their efficacy. In this paper, we proposed a novel Joint 2D–3D Cross-Pseudo Supervision (JCPS) method for accurate carotid vessel wall segmentation.Methods: In this study, a vascular center-of-gravity positioning module was developed to automatically estimate the region of blood vessels. To achieve accurate segmentation, we proposed a joint 2D–3D semi-supervised network to model the three-dimensional continuity of vascular structure. In addition, a novel loss function tailored for vessel segmentation was introduced, consisting of four components: supervision loss, cross-pseudo supervision loss, pseudo label supervision loss, and continuous supervision loss, all aimed at ensuring the accuracy and continuity of the vessel structure. In what followed, we also built up a user-friendly Graphical User Interface based on our JCPS method for end-users.Results: Our proposed JCPS method was evaluated using the Carotid Artery Vessel Wall Segmentation Challenge dataset to assess its performance. The experimental results clearly indicated that our approach surpassed the top 10 methods on the leaderboard, resulting in a significant enhancement in segmentation accuracy. Specifically, we achieved an average Dice similarity coefficient increase from 0.775 to 0.806 and an average quantitative score improvement from 0.837 to 0.850, demonstrating the effectiveness of our proposed JCPS method for carotid artery vessel wall segmentation.Conclusion: The experimental results suggested that the JCPS method had a high level of generalization performance by producing pseudo labels that were comparable with software annotations for data-imbalanced segmentation tasks.Keywords
Funding Information
- National Natural Science Foundation of China (NSFC 12071345)
This publication has 38 references indexed in Scilit:
- Fully Convolutional Networks for Semantic SegmentationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2016
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Fully convolutional networks for semantic segmentation2015
- A Level Set Method for Image Segmentation in the Presence of Intensity Inhomogeneities With Application to MRIIEEE Transactions on Image Processing, 2011
- Protein complex detection with semi-supervised learning in protein interaction networksProteome Science, 2011
- Integrating spatial fuzzy clustering with level set methods for automated medical image segmentationComputers in Biology and Medicine, 2011
- Distance Regularized Level Set Evolution and Its Application to Image SegmentationIEEE Transactions on Image Processing, 2010
- Active contours without edgesIEEE Transactions on Image Processing, 2001
- A recursive thresholding technique for image segmentationIEEE Transactions on Image Processing, 1998
- Seeded region growingIEEE Transactions on Pattern Analysis and Machine Intelligence, 1994