Venous Stenosis After Transvenous Lead Placement: A Study of Outcomes and Risk Factors in 212 Consecutive Patients
Open Access
- 25 August 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 4 (8) , e001878
Abstract
Background: Venous stenosis is a common complication of transvenous lead implantation, but the risk factors for venous stenosis have not been well defined to date. This study was designed to evaluate the incidence of and risk factors for venous stenosis in a large consecutive cohort. Methods and Results: A total of 212 consecutive patients (136 male, 76 female; mean age 69 years) with existing pacing or implantable cardioverter‐defibrillator systems presented for generator replacement, lead revision, or device upgrade with a mean time since implantation of 6.2 years. Venograms were performed and percentage of stenosis was determined. Variables studied included age, sex, number of leads, lead diameter, implant duration, insulation material, side of implant, and anticoagulant use. Overall, 56 of 212 patients had total occlusion of the subclavian or innominate vein (26%). There was a significant association between the number of leads implanted and percentage of venous stenosis ( P =0.012). Lead diameter, as an independent variable, was not a risk factor; however, greater sum of the lead diameters implanted was a predictor of subsequent venous stenosis ( P =0.009). Multiple lead implant procedures may be associated with venous stenosis ( P =0.057). No other variables approached statistical significance. Conclusions: A significant association exists between venous stenosis and the number of implanted leads and also the sum of the lead diameters. When combined with multiple implant procedures, the incidence of venous stenosis is increased.Keywords
This publication has 19 references indexed in Scilit:
- In-Hospital Complications Associated With Reoperations of Implantable Cardioverter DefibrillatorsThe American Journal of Cardiology, 2014
- Delayed ICD Lead Cardiac Perforation: Comparison of Small versus Standard‐Diameter Leads Implanted in a Single CenterPacing and Clinical Electrophysiology, 2011
- Incidence and predictors of subclavian vein obstruction following biventricular device implantationJournal of Interventional Cardiac Electrophysiology, 2010
- Delayed Lead Perforation: A Disturbing TrendPacing and Clinical Electrophysiology, 2005
- Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker LeadsJournal of Cardiovascular Electrophysiology, 2004
- Prevalence of central venous occlusion in patients with chronic defibrillator leadsAmerican Heart Journal, 2001
- Bipolar Leads for Use With Permanently Implantable Cardiac Pacing Systems: A Review of Limitations of Traditional and Coaxial Configurations and the Development and Testing of New Conductor, Insulation, and Electrode DesignsJournal of Investigative Surgery, 1997
- Thrombotic complications with pacemakersInternational Journal of Cardiology, 1983
- Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human BeingsNew England Journal of Medicine, 1980
- The Incidence of Venous Thrombosis Following Long-Term Transvenous PacingThe Annals of Thoracic Surgery, 1976