Adaptive intensity modulated proton therapy using 4D robust planning: a proof-of-concept for the application of dose mimicking approach
Open Access
- 13 September 2024
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 185010
Abstract
Objective. A four-dimensional robust optimisation (4DRO) is usually employed when the tumour respiratory motion needs to be addressed. However, it is computationally demanding, and an automated method is preferable for adaptive planning to avoid manual trial-and-error. This study proposes a 4DRO technique based on dose mimicking for automated adaptive planning. Approach. Initial plans for 4DRO intensity modulated proton therapy were created on an average CT for four patients with clinical target volume (CTV) in the lung, oesophagus, or pancreas, respectively. These plans were robustly optimised using three phases of four-dimensional computed tomography (4DCT) and accounting for setup and density uncertainties. Weekly 4DCTs were used for adaptive replanning, using a constant relative biological effectiveness (cRBE) of 1.1. Two methods were used: (1) template-based adaptive (TA) planning and (2) dose-mimicking-based adaptive (MA) planning. The plans were evaluated using variable RBE (vRBE) weighted doses and biologically consistent dose accumulation (BCDA). Main results. MA and TA plans had comparable CTV coverage except for one patient where the MA plan had a higher D98 and lower D2 but with an increased D2 in few organs at risk (OARs). CTV D98 deviations in non-adaptive plans from the initial plans were up to −7.2 percentage points (p.p.) in individual cases and −1.8 p.p. when using BCDA. For the OARs, MA plans showed a reduced mean dose and D2 compared to the TA plans, with few exceptions. The vRBE-weighted accumulated doses had a mean dose and D2 difference of up to 0.3 Gy and 0.5 Gy, respectively, in the OARs with respect to cRBE-weighted doses. Significance. MA plans indicate better performance in target coverage and OAR dose sparing compared to the TA plans in 4DRO adaptive planning. Moreover, MA method is capable of handling both forms of anatomical variation, namely, changes in density and relative shifts in the position of OARs.Keywords
Funding Information
- Horizon 2020 Framework Programme (955956)
This publication has 46 references indexed in Scilit:
- The partial adaptation strategy for online‐adaptive proton therapy: A proof of concept study in head and neck cancer patientsMedical Physics, 2024
- An approach to generate synthetic 4DCT datasets to benchmark Mid-Position implementationsPhysica Medica, 2023
- Deformed dose restoration to account for tumor deformation and position changes for adaptive proton therapyMedical Physics, 2022
- Deep learning–based 4D‐synthetic CTs from sparse‐view CBCTs for dose calculations in adaptive proton therapyMedical Physics, 2022
- Experimental validation of 4D log file‐based proton dose reconstruction for interplay assessment considering amplitude‐sorted 4DCTsMedical Physics, 2022
- Robust automated radiation therapy treatment planning using scenario‐specific dose prediction and robust dose mimickingMedical Physics, 2022
- Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigationsMedical Physics, 2022
- AAPM Task Group Report 290: Respiratory motion management for particle therapyMedical Physics, 2022
- Log file‐based dose reconstruction and accumulation for 4D adaptive pencil beam scanned proton therapy in a clinical treatment planning system: Implementation and proof‐of‐conceptMedical Physics, 2019
- The biologic relevance of daily dose variations in adaptive treatment planningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006