Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography
Open Access
- 5 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (5) , 1964-1971
Abstract
The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters from surface diaphragm electromyography (EMGdi). Twenty healthy volunteers underwent an incremental load respiratory test whilst EMGdi was recorded with a Shimmer3 wearable device (EMGdi W ). Simultaneously, a second EMGdi (EMGdi L ), inspiratory mouth pressure (Pmouth) and lead-I electrocardiogram (ECG) were recorded via a standard wired laboratory acquisition system. Different cardiorespiratory parameters were extracted from both EMGdi W and EMGdi L signals: heart rate, respiratory rate, respiratory muscle activity, and mean frequency of EMGdi signals. Alongside these, similar parameters were also extracted from reference signals (Pmouth and ECG). High correlations were found between the data extracted from the EMGdi W and the reference signal data: heart rate ( R = 0.947), respiratory rate ( R = 0.940), respiratory muscle activity ( R = 0.877), and mean frequency ( R = 0.895). Moreover, similar increments in EMGdi W and EMGdi L activity were observed when Pmouth was raised, enabling the study of respiratory muscle activation. In summary, the Shimmer3 device is a promising and cost-effective solution for the ambulatory monitoring of respiratory muscle function in chronic respiratory diseases.Keywords
Funding Information
- Generalitat de Catalunya
- Spanish Ministry of Economy (DPI2015-68820-R)
- Biomedical Research Networking Center in Bioengineering
- Nacional de Ciencia, Tecnología e Innovación (270-2012-273)
This publication has 29 references indexed in Scilit:
- Monitoring Breathing Rate at Home Allows Early Identification of COPD ExacerbationsChest, 2012
- Resting heart rate is a predictor of mortality in COPDEuropean Respiratory Journal, 2012
- Electromyographic models to assess muscle fatigueJournal of Electromyography and Kinesiology, 2012
- A review of wearable sensors and systems with application in rehabilitationJournal of NeuroEngineering and Rehabilitation, 2012
- Neural respiratory drive as a physiological biomarker to monitor change during acute exacerbations of COPDThorax, 2011
- Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditionsPhysiological Measurement, 2010
- Surface EMG based muscle fatigue evaluation in biomechanicsClinical Biomechanics, 2009
- Inspiratory muscular activation during threshold® therapy in elderly healthy and patients with COPDJournal of Electromyography and Kinesiology, 2005
- Reproducibility and responsiveness of a noninvasive EMG technique of the respiratory muscles in COPD patients and in healthy subjectsJournal of Applied Physiology, 2004
- ATS/ERS Statement on Respiratory Muscle TestingAmerican Journal of Respiratory and Critical Care Medicine, 2002