Investigation of data-driven stopping power calibration of treatment planning x-ray CT from simulated sparse-view proton radiographies
Open Access
- 11 December 2025
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (24) , 245007
Abstract
Objective. Proton therapy treatment planning currently needs to account for relatively large range uncertainty margins primarily due to the semi-empirical calibration of the treatment planning x-ray computed tomography (CT) to proton stopping power relative to water (RSP). Proton radiography enables direct measurement of integral RSP, offering potential to improve calibration and reduce these uncertainties. Approach. Three deep neural network architectures are trained to infer a patient RSP map using the treatment planning CT and proton radiographies, assuming straight proton trajectories. The best suited architecture is then evaluated on more realistic, clinical-like data generated with Monte Carlo simulations. Three idealized proton imaging detectors are simulated: single particle tracking (SPT), a pixelated energy-resolving imager (PERI) and a proton-integrating detector (PID). Main results. The learned primal dual (LPD) architetcure performs best in the simplified imaging scenario. In the more realistic scenario, the initial calibration error (median absolute percentage error of 2.24% across the test set) is reduced using only two projections across all detector types. SPT and PERI reach similar performance (1.10%/1.12%), followed by PID (1.30%). Restricting the LPD to the calibration task by incorporating prior knowledge of the functional relationship of Hounsfield Units (HUs) and RSP further improves calibration performance. For SPT, conventional optimization on detector data acquired for individual protons outperformed the data-driven method (0.16% vs. 1.10%). However, for PERI and PID, the data-driven approach (1.12%/1.30%) slightly outperformed conventional optimization (1.63%/1.72%). Significance. To our knowledge, this is the first study to apply a deep learning-based approach fusing proton radiographies and treatment planning CT data for improved RSP calibration. The method achieves lower calibration errors than idealized, conventional calibration curve optimization on PERIs and PIDs—detector types that offer a promising path for clinical adoption due to their lower complexity and cost compared to SPT systems.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (372393016)
This publication has 50 references indexed in Scilit:
- Consensus guide on CT-based prediction of stopping-power ratio using a Hounsfield look-up table for proton therapyRadiotherapy and Oncology, 2023
- Combining physics‐based models with deep learning image synthesis and uncertainty in intraoperative cone‐beam CT of the brainMedical Physics, 2023
- The use of deep learning methods in low-dose computed tomography image reconstruction: a systematic reviewComplex & Intelligent Systems, 2022
- A back‐projection‐and‐filtering‐like (BPF‐like) reconstruction method with the deep learning filtration from listmode data in TOF‐PETMedical Physics, 2022
- Refinement of the Hounsfield look‐up table by retrospective application of patient‐specific direct proton stopping‐power prediction from dual‐energy CTMedical Physics, 2020
- An inhomogeneous most likely path formalism for proton computed tomographyPhysica Medica, 2020
- In vivo range verification in particle therapyMedical Physics, 2018
- Theoretical and experimental analysis of photon counting detector CT for proton stopping power predictionMedical Physics, 2018
- Inter-centre variability of CT-based stopping-power prediction in particle therapy: Survey-based evaluationPhysics and Imaging in Radiation Oncology, 2018
- Development of a fast proton range radiography system for quality assurance in hadrontherapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013