MRI surface-coil pair with strong inductive coupling
- 1 December 2016
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (12) , 124704
Abstract
A novel inductively coupled coil pair was used to obtain magnetic resonance phantom images. Rationale for using such a structure is described in R. R. Mett et al. [Rev. Sci. Instrum. 87, 084703 (2016)]. The original rationale was to increase the Q-value of a small diameter surface coil in order to achieve dominant loading by the sample. A significant improvement in the vector reception field (VRF) is also seen. The coil assembly consists of a 3-turn 10 mm tall meta-metallic self-resonant spiral (SRS) of inner diameter 10.4 mm and outer diameter 15.1 mm and a single-loop equalization coil of 25 mm diameter and 2 mm tall. The low-frequency parallel mode was used in which the rf currents on each coil produce magnetic fields that add constructively. The SRS coil assembly was fabricated and data were collected using a tissue-equivalent 30% polyacrylamide phantom. The large inductive coupling of the coils produces phase-coherency of the rf currents and magnetic fields. Finite-element simulations indicate that the VRF of the coil pair is about 4.4 times larger than for a single-loop coil of 15 mm diameter. The mutual coupling between coils influences the current ratio between the coils, which in turn influences the VRF and the signal-to-noise ratio (SNR). Data on a tissue-equivalent phantom at 9.4 T show a total SNR increase of 8.8 over the 15 mm loop averaged over a 25 mm depth and diameter. The experimental results are shown to be consistent with the magnetic resonance theory of the emf induced by spins in a coil, the theory of inductively coupled resonant circuits, and the superposition principle. The methods are general for magnetic resonance and other types of signal detection and can be used over a wide range of operating frequencies.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (P41 EB001980, R01 EB000215)
This publication has 18 references indexed in Scilit:
- Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 TMagnetic Resonance in Medicine, 2010
- Dielectric microwave resonators in TE011 cavities for electron paramagnetic resonance spectroscopyReview of Scientific Instruments, 2008
- NMR spiral surface microcoils: Design, fabrication, and imagingConcepts in Magnetic Resonance Part B, 2003
- Use of mutually inductive coupling in probe designConcepts in Magnetic Resonance, 2002
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- A high‐sensitivity, high‐B1 homogeneity probe for quantitation of metabolitesMagnetic Resonance in Medicine, 1990
- Use of polyacrylamide as a tissue-equivalent material in the microwave rangeIEEE Transactions on Biomedical Engineering, 1988
- Counter rotating current local coils for high‐resolution magnetic resonance imagingMagnetic Resonance in Medicine, 1986
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- Thermal Agitation of Electric Charge in ConductorsPhysical Review B, 1928