Implant survival after deep infection of an instrumented spinal fusion
- 1 August 2013
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 95-B (8) , 1121-1126
Abstract
This study evaluates the long-term survival of spinal implants after surgical site infection (SSI) and the risk factors associated with treatment failure. A Kaplan-Meier survival analysis was carried out on 43 patients who had undergone a posterior spinal fusion with instrumentation between January 2006 and December 2008, and who consecutively developed an acute deep surgical site infection. All were appropriately treated by surgical debridement with a tailored antibiotic program based on culture results for a minimum of eight weeks. A ‘terminal event’ or failure of treatment was defined as implant removal or death related to the SSI. The mean follow-up was 26 months (1.03 to 50.9). A total of ten patients (23.3%) had a terminal event. The rate of survival after the first debridement was 90.7% (95% confidence interval (CI) 82.95 to 98.24) at six months, 85.4% (95% CI 74.64 to 96.18) at one year, and 73.2% (95% CI 58.70 to 87.78) at two, three and four years. Four of nine patients required re-instrumentation after implant removal, and two of the four had a recurrent infection at the surgical site. There was one recurrence after implant removal without re-instrumentation. Multivariate analysis revealed a significant risk of treatment failure in patients who developed sepsis (hazard ratio (HR) 12.5 (95% confidence interval (CI) 2.6 to 59.9); p < 0.001) or who had > three fused segments (HR 4.5 (95% CI 1.25 to 24.05); p = 0.03). Implant survival is seriously compromised even after properly treated surgical site infection, but progressively decreases over the first 24 months. Cite this article: Bone Joint J 2013;95-B:1121–6.Keywords
This publication has 25 references indexed in Scilit:
- The Influence of Perioperative Risk Factors and Therapeutic Interventions on Infection Rates After Spine SurgerySpine, 2010
- Closed Suction Irrigation for the Treatment of Postoperative Wound Infections Following Posterior Spinal Fusion and InstrumentationSpine, 2010
- Infection Rate after Spine Surgery in Cerebral Palsy is High and Impairs Results: Multicenter Analysis of Risk Factors and TreatmentClinical Orthopaedics and Related Research, 2010
- Clinical Outcome of Deep Wound Infection After Instrumented Posterior Spinal FusionSpine, 2009
- Failure of Attempted Implant Retention in Spinal Deformity Delayed Surgical Site InfectionsSpine, 2009
- Therapy of Spinal Wound Infections Using Vacuum-assisted Wound Closure: Risk Factors Leading to Resistance to TreatmentJournal of Spinal Disorders & Techniques, 2008
- Trends and Variations in the Use of Spine SurgeryClinical Orthopaedics and Related Research, 2006
- New Approaches for the Characterization of Prosthetic Joint BiofilmsClinical Orthopaedics and Related Research, 2005
- Postoperative Wound Infection after Instrumentation of Thoracic and Lumbar FracturesJournal of Orthopaedic Trauma, 2001
- Pseudarthrosis After Postoperative Wound Infection in the Lumbar SpineJournal of Spinal Disorders, 1997