The reliability of a simulated uphill time trial using the Velotron electronic bicycle ergometer
Authors:
- 5 June 2010
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 110 (3) , 499-506
Abstract
This study was conducted to measure the reliability of an indoor uphill time trial (TT) using the Velotron electronic bicycle ergometer with a computer-generated pacer that represented a subject’s prior TT performance. A total of 12 trained cyclists (42 ± 7.79 years, 63.0 ± 6.12 ml/kg/min) completed three 8-mile uphill TT with 2–7 days between subsequent tests. A repeated measure ANOVA found no difference between finishing times for TT1 (2,154 ± 246 s) and TT2 (2,078 ± 185 s, p = 0.055) or TT2 and TT3 (2,047 ± 167 s, p = 0.075). All measures of reliability showed an increased reliability for finishing times in TT2–TT3 [95% CI for: coefficient of variation (CV) = 1.0–2.3%, intraclass correlation coefficient (ICC) = 0.953–0.996, standard error of measurement (SEM) = 2.1–4.9 s] versus TT1–TT2 (95% CI for: CV = 2.0–4.9%, ICC = 0.827–0.986, SEM = 9.8–23 s). An uphill TT using the Velotron bicycle ergometer with a prior performance as a pacer is a reliable assessment for indoor TT performance testing, but a familiarization trial improves reliability. Although there were no significant differences found for completion times between TT1–TT2 or TT2–TT3, the absolute mean differences, small sample size and low p values may be suggestive of a Type II error.Keywords
This publication has 23 references indexed in Scilit:
- Validity and Reliability of the Ergomo®pro PowermeterInternational Journal of Sports Medicine, 2008
- Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle ErgometersInternational Journal of Sports Medicine, 2005
- Quantifying Test-Retest Reliability Using the Intraclass Correlation Coefficient and the SEMJournal of Strength & Conditioning Research, 2005
- Reproducibility of a Laboratory-Based 40-km Cycle Time-Trial on a Stationary Wind-Trainer in Highly Trained CyclistsInternational Journal of Sports Medicine, 2003
- Reproducibility of the Cycling Time to Exhaustion at in Highly Trained CyclistsCanadian Journal of Applied Physiology, 2003
- The Validity of Power Output Recorded During Exercise Performance Tests Using a Kingcycle Air-Braked Cycle Ergometer When Compared With an SRM PowermeterInternational Journal of Sports Medicine, 2000
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle ErgometerInternational Journal of Sports Medicine, 1996
- Variability of Time to Exhaustion During Submaximal ExerciseCanadian Journal of Applied Physiology, 1995
- Day to Day Variation in Time Trial Cycling PerformanceInternational Journal of Sports Medicine, 1992