Influence of chemical species on the determination of arsenic using inductively coupled plasma mass spectrometry at a low liquid flow rate
- 10 July 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 28 (11) , 1718-1724
Abstract
The effect of common arsenic species on the ICP-MS signal working at a low liquid flow rate was investigated, taking into account the influence of the analytical concentration and of the matrix, comparing various sample introduction systems. Significant decrease (up to 65%) in the relative sensitivity of arsenite compared to arsenate was found, while methylarsonate, dimethylarsinate and arsenobetaine gave the same response (within 6%) as arsenate, throughout the 20–1000 μL min−1 liquid flow rate range. The effect was independent of the analytical concentration in the 1–100 μg L−1 range, and it was ascribed to processes related to both the sample introduction system and the ion generation and transport. Ion defocussing due to dissimilar kinetic energy of the arsenic ions generated from arsenite and arsenate was ruled out. Results obtained by various micronebulizer/spray chamber configurations showed that the temperature of the spray chamber is relevant in determining the relative responses of the arsenic species: heating the spray chamber at 60 °C caused a decrease in relative sensitivity of arsenite and dimethylarsinate compared to arsenate, while the arsenite-to-arsenate signal ratio was improved by cooling at 4 °C. The relative response of arsenite and arsenate was also significantly influenced by the presence of ammonium phosphate, which mitigated the difference between the species using conventional sample introduction devices. The influence of the chemical species on the ICP-MS signal was also investigated for species of other elements, finding significant differences in sensitivity for Hg, Se and Sn compounds when working at a low liquid flow rate. The results proved to have an effect on the accurate quantification of total concentration, as well as for arsenic speciation analysis by μHPLC/ICP-MS.Keywords
This publication has 33 references indexed in Scilit:
- Inductively coupled plasma mass spectrometry (ICP MS): a versatile toolJournal of Mass Spectrometry, 2007
- Consequences of Vapor Enhancement on Selenium Speciation Analysis by HPLC/ICPMSAnalytical Chemistry, 2006
- Sample introduction systems for reversed phase LC-ICP-MS of selenium using large amounts of methanol—comparison of systems based on membrane desolvation, a spray chamber and direct injectionJournal of Analytical Atomic Spectrometry, 2005
- Comparison of a direct injection nebulizer and a micronebulizer associated with a spray chamber for the determination of iodine in the form of volatile CH3I by inductively coupled plasma sector field mass spectrometryJournal of Analytical Atomic Spectrometry, 2002
- Comparison of an ultrasonic nebulizer with a cross-flow nebulizer for selenium speciation by ion-chromatography and inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2000
- Speciation of tin by reversed phase liquid chromatography with inductively coupled plasma mass spectrometric detectionAnalytica Chimica Acta, 1995
- Speciation of organotin compounds using inductively coupled plasma mass spectrometry with micellar liquid chromatographyJournal of Analytical Atomic Spectrometry, 1995
- Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciationJournal of Analytical Atomic Spectrometry, 1994
- Speciation of mercury by reversed-phase liquid chromatography with inductively coupled plasma mass spectrometric detectionJournal of Analytical Atomic Spectrometry, 1993
- Inductively coupled plasma mass spectrometric detection for multielement flow injection analysis and elemental speciation by reversed-phase liquid chromatographyAnalytical Chemistry, 1986