Acute vital signs changes are underrepresented by a conventional electronic health record when compared with automatically acquired data in a single-center tertiary pediatric cardiac intensive care unit
- 18 March 2022
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of the American Medical Informatics Association
- Vol. 29 (7) , 1183-1190
Abstract
Objective: We sought to evaluate the fidelity with which the patient’s clinical state is represented by the electronic health record (EHR) flow sheet vital signs data compared to a commercially available automated data aggregation platform in a pediatric cardiac intensive care unit (CICU) Methods: This is a retrospective observational study of heart rate (HR), systolic blood pressure (SBP), respiratory rate (RR), and pulse oximetry (SpO2) data archived in a conventional EHR and an automated data platform for 857 pediatric patients admitted postoperatively to a tertiary pediatric CICU. Automated data captured for 72 h after admission were analyzed for significant HR, SBP, RR, and SpO2 deviations from baseline (events). Missed events were identified when the EHR failed to reflect the events reflected in the automated platform Results: Analysis of 132 054 622 data entries, including 264 966 (0.2%) EHR entries and 131 789 656 (99.8%) automated entries, identified 15 839 HR events, 5851 SBP events, 9648 RR events, and 2768 SpO2 events lasting 3–60 min; these events were missing in the EHR 48%, 58%, 50%, and 54% of the time, respectively. Subanalysis identified 329 physiologically implausible events (eg, likely operator or device error), of which 104 (32%) were nonetheless documented in the EHR Conclusion: In this single-center retrospective study of CICU patients, EHR vital sign documentation was incomplete compared to an automated data aggregation platform. Significant events were underrepresented by the conventional EHR, regardless of event duration. Enrichment of the EHR with automated data aggregation capabilities may improve representation of patient conditionKeywords
This publication has 21 references indexed in Scilit:
- Electronic Health Records: Then, Now, and in the FutureYearbook of Medical Informatics, 2016
- Association between exposure to nonactionable physiologic monitor alarms and response time in a children's hospitalJournal of Hospital Medicine, 2015
- A Comparison of Oxygen Saturation Data in Inpatients with Low Oxygen Saturation Using Automated Continuous Monitoring and Intermittent Manual Data ChartingAnesthesia & Analgesia, 2014
- Clinical Benefits of Electronic Health Record Use: National FindingsHealth Services Research, 2013
- Use and Satisfaction with Electronic Health Record by Primary Care Physicians in a Health District in BrazilJournal of Medical Systems, 2011
- Benefits and drawbacks of electronic health record systemsRisk Management and Healthcare Policy, 2011
- Electronic Health Record Adoption – Maybe It’s not about the MoneyApplied Clinical Informatics, 2011
- A comparison of vital signs charted by nurses with automated acquired values using waveform quality indicesJournal of Clinical Monitoring and Computing, 2009
- Primary care physician time utilization before and after implementation of an electronic health record: A time-motion studyJournal of Biomedical Informatics, 2005
- The Impact of Electronic Health Records on Time Efficiency of Physicians and Nurses: A Systematic ReviewJournal of the American Medical Informatics Association, 2005