Ventilation from four-dimensional computed tomography: density versus Jacobian methods
Authors:
- Richard CastilloRCRichard Castillo
- Edward CastilloECEdward Castillo
- Josue MartinezJMJosue Martinez
- Thomas GuerreroTGThomas Guerrero
- 30 July 2010
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (16) , 4661-4685
Abstract
Two calculation methods to produce ventilation images from four-dimensional computed tomography (4DCT) acquired without added contrast have been reported. We reported a method to obtain ventilation images using deformable image registration (DIR) and the underlying CT density information. A second method performs the ventilation image calculation from the DIR result alone, using the Jacobian determinant of the deformation field to estimate the local volume changes resulting from ventilation. For each of these two approaches, there are variations on their implementation. In this study, two implementations of the Jacobian-based methodology are evaluated, as well as a single density change-based model for calculating the physiologic specific ventilation from 4DCT. In clinical practice, (99m)Tc-labeled aerosol single photon emission computed tomography (SPECT) is the standard method used to obtain ventilation images in patients. In this study, the distributions of ventilation obtained from the CT-based ventilation image calculation methods are compared with those obtained from the clinical standard SPECT ventilation imaging. Seven patients with 4DCT imaging and standard (99m)Tc-labeled aerosol SPECT/CT ventilation imaging obtained on the same day as part of a prospective validation study were selected. The results of this work demonstrate the equivalence of the Jacobian-based methodologies for quantifying the specific ventilation on a voxel scale. Additionally, we found that both Jacobian- and density-change-based methods correlate well with global measurements of the resting tidal volume. Finally, correlation with the clinical SPECT was assessed using the Dice similarity coefficient, which showed statistically higher (p-value < 10(-4)) correlation between density-change-based specific ventilation and the clinical reference than did either Jacobian-based implementation.Keywords
This publication has 45 references indexed in Scilit:
- Four-dimensional deformable image registration using trajectory modelingPhysics in Medicine & Biology, 2009
- Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation studyRadiotherapy and Oncology, 2009
- A framework for evaluation of deformable image registration spatial accuracy using large landmark point setsPhysics in Medicine & Biology, 2009
- Comparison Between Radioactive Aerosol, Technegas and Krypton for Ventilation Imaging in Healthy CalvesThe Veterinary Journal, 2000
- Noninvasive assessment of regional ventilation in the human lung using oxygen–enhanced magnetic resonance imagingNature Medicine, 1996
- Biological magnetic resonance imaging using laser-polarized 129XeNature, 1994
- Lung cancer in patients with borderline lung functions - zonal lung perfusion scans at presentation and lung function after high dose irradiationRadiotherapy and Oncology, 1990
- Technegas - a new ventilation agent for lung scanningNuclear Medicine Communications, 1986
- Scintigraphic evaluation of regional pulmonary ventilationSeminars in Nuclear Medicine, 1980
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945