Biologically informed geometry and force distribution improve task performance in agonist/antagonist tendon-driven prosthetic hands
Preprint
Abstract
Prosthetic devices balance functionality and usability to support activities of daily living (ADLs). However, many designs rely on rigid end effectors that, while anthropomorphic in form, lack biomimetic design principles. This mismatch increases cognitive and physical burden, reducing adoption rates. We developed the Human-inspired Actuator Modeling and Reconstruction (HAMR) process, a user-centered framework informed by individual morphology and functional needs, to generate customized agonist/antagonist tendon-actuated end effectors. Using HAMR, we created the Tendon Actuated Prosthetic Hand (TAPH), which integrates human-derived geometry with adaptive force distribution to promote natural object interaction. In a study with 12 participants without limb difference, TAPH was compared to a structurally similar tendon-actuated hand with generalized anthropomorphic geometry across three ADL tasks of varying complexity. TAPH significantly improved task performance and reduced physical effort, mental workload, and frustration, particularly during gross motor tasks. For fine motor tasks, performance improved under stable conditions but not during tasks requiring dynamic precision and continuous coordination. These findings highlight the functional benefits of biologically informed prosthesis design and support biomimetic principles in enhancing performance and user experience.Keywords
This publication has 23 references indexed in Scilit:
- Understanding the Utility of State-Based Haptic Feedback in Tendon-driven Anthropomorphic ProsthesesmedRxiv, 2025
- Realistic Model Parameter Optimization: Shadow Robot Dexterous Hand Use-Case2024
- Haptic shared control improves neural efficiency during myoelectric prosthesis useScientific Reports, 2023
- Investigation of reliability, validity, and cutoff value of the Jebsen-Taylor Hand Function TestJournal of Hand Therapy, 2021
- Current rates of prosthetic usage in upper-limb amputees – have innovations had an impact on device acceptance?Disability and Rehabilitation, 2020
- A Wearable Anthropomorphically-Driven Prosthesis with a Built-In Haptic Feedback System2020
- Comparative clinical evaluation of the Yale Multigrasp Hand2016
- Upper limb prosthesis use and abandonmentProsthetics and Orthotics International, 2007
- Design of the TUAT/Karlsruhe humanoid hand2002