Implementation of LED Fluorescence Microscopy for Diagnosis of Pulmonary and HIV-Associated Tuberculosis in a Hospital Setting in Indonesia
Open Access
- 19 April 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e61727
Abstract
Fluorescence microscopy (FM) has not been implemented widely in TB endemic settings and little evaluation has been done in HIV-infected patients. We evaluated diagnostic performance, time and costs of FM with light-emitting diodes technology (LED-FM), compared with conventional (Zieh-Neelsen) microscopy in a hospital in Indonesia which acts as referral centre for HIV-infected patients. We included pulmonary tuberculosis suspects from the outpatient and HIV clinic. Direct and concentrated sputum smears were examined using LED-FM and ZN microscopy by two technicians who were blinded for the HIV-status and the result of the comparative test. Mean reading time per slide was recorded and cost of each slide was calculated. Mycobacteria culture served as the reference standard. Among 404 tuberculosis suspects from the outpatient clinic and 256 from the HIV clinic, mycobacteria culture was positive in 12.6% and 27%, respectively. The optimal sensitivity of LED-FM was achieved by using a threshold of ≥2 AFB/length. LED-FM had a higher sensitivity (75.5% vs. 54.9%, P<0.01) but lower specificity (90.0% vs 96.6%, P<0.01) compared to ZN microscopy. HIV was associated with a lower sensitivity but similar specificity. The average reading time using LED-FM was significantly shorter (2.23±0.78 vs 5.82±1.60 minutes, P<0.01), while costs per slide were similar. High sensitivity of LED-FM combined with shorter reading time of sputum smear slides make this method a potential alternative to ZN microscopy. Additional data on specificity are needed for effective implementation of this technique in high burden TB laboratories.Keywords
This publication has 24 references indexed in Scilit:
- Rapid Diagnosis of Pulmonary and Extrapulmonary Tuberculosis in HIV-Infected Patients. Comparison of LED Fluorescent Microscopy and the GeneXpert MTB/RIF Assay in a District Hospital in IndiaTuberculosis Research and Treatment, 2012
- LED Fluorescence Microscopy for the Diagnosis of Pulmonary Tuberculosis: A Multi-Country Cross-Sectional EvaluationPLOS Medicine, 2011
- Evaluation of Combined LED-Fluorescence Microscopy and Bleach Sedimentation for Diagnosis of Tuberculosis at Peripheral Health Service LevelPLOS ONE, 2011
- Mycobacterium tuberculosisBeijing Genotype Is an Independent Risk Factor for Tuberculosis Treatment Failure in IndonesiaThe Journal of Infectious Diseases, 2010
- Voluntary counselling and testing uptake and HIV prevalence among tuberculosis patients in Jogjakarta, IndonesiaTransactions of the Royal Society of Tropical Medicine and Hygiene, 2008
- The future looks bright: low-cost fluorescent microscopes for detection of Mycobacterium tuberculosis and CoccidiaeTransactions of the Royal Society of Tropical Medicine and Hygiene, 2008
- Facing the Crisis: Improving the Diagnosis of Tuberculosis in the HIV EraThe Journal of Infectious Diseases, 2007
- Epidemiology of Tuberculosis in a High HIV Prevalence Population Provided with Enhanced Diagnosis of Symptomatic DiseasePLOS Medicine, 2007
- Efficacy of fluorochrome stain in the diagnosis of pulmonary tuberculosis co-infected with HIVIndian Journal of Medical Microbiology, 2005
- Scanty AFB smears: what's in a name?2004