Quantification of Right and Left Ventricular Function in Cardiac MR Imaging: Comparison of Semiautomatic and Manual Segmentation Algorithms
Open Access
- 3 April 2013
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 3 (2) , 271-282
Abstract
The purpose of this study was to evaluate the performance of a semiautomatic segmentation method for the anatomical and functional assessment of both ventricles from cardiac cine magnetic resonance (MR) examinations, reducing user interaction to a “mouse-click”. Fifty-two patients with cardiovascular diseases were examined using a 1.5-T MR imaging unit. Several parameters of both ventricles, such as end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF), were quantified by an experienced operator using the conventional method based on manually-defined contours, as the standard of reference; and a novel semiautomatic segmentation method based on edge detection, iterative thresholding and region growing techniques, for evaluation purposes. No statistically significant differences were found between the two measurement values obtained for each parameter (p > 0.05). Correlation to estimate right ventricular function was good (r > 0.8) and turned out to be excellent (r > 0.9) for the left ventricle (LV). Bland-Altman plots revealed acceptable limits of agreement between the two methods (95%). Our study findings indicate that the proposed technique allows a fast and accurate assessment of both ventricles. However, further improvements are needed to equal results achieved for the right ventricle (RV) using the conventional methodology.Keywords
This publication has 29 references indexed in Scilit:
- A review of segmentation methods in short axis cardiac MR imagesMedical Image Analysis, 2011
- Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision supportJournal of Cardiovascular Magnetic Resonance, 2011
- Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validationJournal of Cardiovascular Magnetic Resonance, 2011
- A comparison of visual and quantitative assessment of left ventricular ejection fraction by cardiac magnetic resonanceThe International Journal of Cardiovascular Imaging, 2010
- Segmentation of cardiac cine MR images of left and right ventricles: Interactive semiautomated methods and manual contouring by two readers with different education and experienceJournal of Magnetic Resonance Imaging, 2008
- Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level‐set modelsMagnetic Resonance in Medicine, 2007
- Single‐breathhold, four‐dimensional, quantitative assessment of LV and RV function using triggered, real‐time, steady‐state free precession MRI in heart failure patientsJournal of Magnetic Resonance Imaging, 2005
- Assessment of left ventricular function by breath‐hold cine MR imaging: Comparison of different steady‐state free precession sequencesJournal of Magnetic Resonance Imaging, 2005
- Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequencesJournal of Magnetic Resonance Imaging, 2003
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986