A soft 3-DOF interaction force measurement system for estimating the biomechanical effects of a soft wearable robot on the human joint
Open Access
- 15 July 2025
- journal article
- research article
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 6, e32
Abstract
Recent advancements in wearable robots have focused on developing soft, compliant, and lightweight structures to provide comfort for the users and to achieve the primary function of assisting body motions. The interaction forces induced by physical human-robot interaction (pHRI) not only cause skin discomfort or pain due to relatively high localized pressures but also degrade the wearability and the safety of the wearer’s joints by unnaturally altering the joint reaction forces (JRFs) and the joint reaction moments (JRMs). Although the correlation between excessive JRFs/JRMs and joint-related conditions has been reported by researchers, the biomechanical effects of forces and moments caused by the pHRI of a wearable robot on the wearer’s joints remain under-analyzed. In this study, we propose a method of measuring and analyzing these interactions and effects, using a custom-designed soft, three-degree-of-freedom (DOF) force sensor. The sensor is made of four Hall effect sensors and a neodymium magnet embedded in a silicone elastomer structure, enabling simultaneous measurement of normal and two-axis shear forces by detecting the distance changes between the magnet and each Hall effect sensor. These sensors are embedded in contact pads of a commercial wearable robot and measure the interaction forces, used for calculating JRF and JRM. We also propose a modified inverse dynamics approach that allows us to consider the physical interactions between the robot and the human body. The proposed method of sensing and analysis provides the potential to enhance the design of future wearable robots, ensuring long-term safety.Keywords
This publication has 58 references indexed in Scilit:
- Soft Wearable Rehabilitation Robots with Artificial Muscles based on Smart Materials: A ReviewAdvanced Intelligent Systems, 2023
- Multibody modeling of the musculoskeletal system2023
- ISB recommendations on the reporting of intersegmental forces and moments during human motion analysisJournal of Biomechanics, 2020
- The History and Future of LEGS2017
- Higher medially-directed joint reaction forces are a characteristic of dysplastic hips: A comparative study using subject-specific musculoskeletal modelsJournal of Biomechanics, 2017
- Minimizing human-exoskeleton interaction force by using global fast sliding mode controlInternational Journal of Control, Automation, and Systems, 2016
- Does high weight loss in older adults with knee osteoarthritis affect bone-on-bone joint loads and muscle forces during walking?Osteoarthritis and Cartilage, 2011
- Subject-specific hip geometry and hip joint centre location affects calculated contact forces at the hip during gaitJournal of Biomechanics, 2009
- Anterior hip joint force increases with hip extension, decreased gluteal force, or decreased iliopsoas forceJournal of Biomechanics, 2007
- Knee adduction moment and development of chronic knee pain in eldersArthritis Care & Research, 2004