Efficacy of two Ni‐Ti systems and hand files for removing gutta‐percha from root canals
- 16 August 2011
- journal article
- research article
- Published by Wiley in International Endodontic Journal
- Vol. 45 (1) , 1-6
Abstract
Mollo A, Botti G, Prinicipi Goldoni N, Randellini E, Paragliola R, Chazine M, Ounsi HF, Grandini S. Efficacy of two Ni‐Ti systems and hand files for removing gutta‐percha from root canals. International Endodontic Journal, 45, 1–6, 2012. Aim To compare the effectiveness of two Ni‐Ti systems and hand files for removing gutta‐percha and sealer from root canals.Methodology The root canals of 60 single‐rooted human teeth were prepared, filled with gutta‐percha and sealer (Pulp Canal Sealer; SybronEndo, Orange, CA, USA). Specimens were then divided into three groups (n = 20), and root filling material was removed using MTwo Retreatment Files (group 1); R‐Endo (group 2); K‐files and Gates‐Glidden drills (group 3). After retreatment, the efficacy of each technique was assessed using radiographs that were later digitized and the images analysed using AutoCAD 2004. The percentage of residual gutta‐percha was calculated for the whole canal as well as for the coronal, middle and apical thirds. Time required, apically extruded debris and the number of fractured instruments were also recorded. Data were statistically analysed using Kruskal–Wallis and Mann–Whitney U‐tests.Results All instrumentation techniques left gutta‐percha and sealer remnants inside the root canals. Ni‐Ti systems were significantly faster (P < 0.05) than the manual technique and significantly more effective (P < 0.05) in removing gutta‐percha particularly from the middle and apical thirds of the root canal. R‐Endo instrumentation was significantly more effective (P < 0.05) than MTwo retreatment files in removing gutta‐percha from the middle and apical thirds. R‐Endo instruments were associated with the least number of cases of apical extrusion. One MTwo instrument fractured.Conclusions The Ni‐Ti systems were more effective and faster than hand files, although all techniques left gutta‐percha and sealer remnants on the root canals.Keywords
This publication has 21 references indexed in Scilit:
- Efficacy of ProTaper Universal rotary retreatment system for gutta‐percha removal from root canalsInternational Endodontic Journal, 2007
- Effectiveness of two nickel‐titanium rotary instruments and a hand file for removing gutta‐percha in severely curved root canals during retreatment: an ex vivo studyInternational Endodontic Journal, 2007
- Efficacy of automated versus hand instrumentation during root canal retreatment: an ex vivo studyInternational Endodontic Journal, 2006
- Ex vivo study of the efficacy of H‐files and rotary Ni–Ti instruments to remove gutta‐percha and four types of sealerInternational Endodontic Journal, 2006
- A comparative study of Endoflare–Hero Shaper and Mtwo NiTi instruments in the preparation of curved root canalsInternational Endodontic Journal, 2005
- Effectiveness in cleaning oval‐shaped root canals using Anatomic Endodontic Technology, ProFile and manual instrumentation: a scanning electron microscopic studyInternational Endodontic Journal, 2005
- Effectiveness of different techniques for removing gutta‐percha during retreatmentInternational Endodontic Journal, 2004
- Efficacy, cleaning ability and safety of different rotary NiTi instruments in root canal retreatmentInternational Endodontic Journal, 2004
- Efficacy, cleaning ability and safety of different devices for gutta‐percha removal in root canal retreatmentInternational Endodontic Journal, 1997
- Efficacy, cleaning ability and safety of different devices for gutta-percha removal in root canal retreatmentInternational Endodontic Journal, 1997