CT Screening and Follow-Up of Lung Nodules: Effects of Tube Current–Time Setting and Nodule Size and Density on Detectability and of Tube Current–Time Setting on Apparent Size
Authors:
- 1 September 2011
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (3) , 623-630
Abstract
OBJECTIVE. The purpose of the study was to quantify and compare the effect of CT dose and of size and density of nodules on the detectability of lung nodules and to quantify the influence of CT dose on the size of the nodules. MATERIALS AND METHODS. From 50 patients a total of 125 cuboidal regions of interest (3 × 3 × 1.5 cm volumes) showing a single nodule (≤ 8 mm) and 27 normal cuboids were selected. Image sets were reconstructed with the software from raw data simulating different dose levels: 300 (original dose), 220, 180, 140, 100, 80, 60, 50, 40, 30, 20, 10, and 5 reference mAs. A logistic regression model was used to analyze detectability for three blinded readers. Odds ratios were calculated for nodule size smaller than 3 mm versus 3 mm and larger and for nodule attenuation of –300 HU and greater versus less than –300 HU. RESULTS. Tube current–time settings of 10 mAs and greater were not associated with a significant difference in individual reader sensitivity compared with the standard setting of 300 mAs. At 5 mAs only one reader had a significant decrease in sensitivity, from 82% to 77% (p = 0.0035). According to the odds ratios and logistic regression results, the strongest negative effect on sensitivity can be assumed for low nodule density followed by small nodule size and dose level. The mean nodule volume measurement error between 5 and 300 mAs was 2.2% ± 18% (SD) and much lower than the interobserver volume measurement error rate of 38% ± 45%. CONCLUSION. The results show the feasibility of a low-dose CT protocol at 10 mAs for follow-up of lung nodules. Computer-aided volume measurement in follow-up of lung nodules decreases interobserver variability.Keywords
This publication has 26 references indexed in Scilit:
- Linear and Volume Measurements of Pulmonary Nodules at Different CT Dose Levels – Intrascan and Interscan AnalysisRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2008
- Performance evaluation of a computer-aided detection algorithm for solid pulmonary nodules in low-dose and standard-dose MDCT chest examinations and its influence on radiologistsBritish Journal of Radiology, 2008
- Variability of Semiautomated Lung Nodule Volumetry on Ultralow-Dose CT: Comparison with Nodule Volumetry on Standard-Dose CTJournal of Digital Imaging, 2008
- Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom studyPhysics in Medicine & Biology, 2008
- The Effect of Lung Volume on Nodule Size on CTAcademic Radiology, 2007
- Evaluation of Lung MDCT Nodule Annotation Across Radiologists and MethodsAcademic Radiology, 2006
- Detektion pulmonaler Rundherde mit der Ultra-low-dose-CT im Rahmen der onkologischen NachsorgeRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2005
- CT Screening for Lung CancerAmerican Journal of Roentgenology, 2002
- Tumor doubling time and prognostic assessment of patients with primary lung cancerCancer, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986