Kinematic Comparison of Myoelectric and Body Powered Prostheses While Performing Common Activities
Authors:
- Stephanie Lutton CareySCStephanie Lutton Carey
- Rajiv V. DubeyRDRajiv V. Dubey
- Greg S. BauerGBGreg S. Bauer
- M. Jason HighsmithMHM. Jason Highsmith
Open Access
- 1 June 2009
- journal article
- case report
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 33 (2) , 179-186
Abstract
This study examined the kinematic differences of a bilateral transradial amputee using myoelectric and body-powered prostheses during select activities of daily living. First in harness suspended, body powered then self-suspended externally powered prostheses, the subject's shoulder and elbow joint movements were calculated and compared while completing an elbow range of motion test, simulated drinking from an empty cup, and opening a door. In this case, body-powered prostheses allowed for greater range of elbow flexion but required more shoulder flexion to complete the tasks that required continuous grasp. While using myoelectric prostheses, the user was able to compensate for limited elbow flexion by flexing the shoulder.Keywords
This publication has 4 references indexed in Scilit:
- Compensatory movements of transradial prosthesis users during common tasksClinical Biomechanics, 2008
- Kinematic Evaluation of Terminal Devices for Kayaking With Upper Extremity AmputationJPO Journal of Prosthetics and Orthotics, 2007
- Myoelectric and Body-Powered ProsthesesJournal of Pediatric Orthopaedics, 1993
- Prosthetic Use in Adult Upper Limb AmputeesProsthetics and Orthotics International, 1986