Chronologic Changes and Correlates of Loop Diuretic Dose in Patients with Left Ventricular Assist Device
- 1 November 2017
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 63 (6) , 774-780
Abstract
No study has systematically evaluated the prevalence and dosages of diuretic use for patients after left ventricular assist device (LVAD) implantation. The primary objective was to characterize chronological change in prevalence and doses of loop diuretics after LVAD placement. The secondary objective was to identify correlates of actual doses of loop diuretics. We retrospectively reviewed medical records of adult patients with LVAD implantation at the University of Kentucky. Prevalence of diuretic use and furosemide equivalent dose were assessed before LVAD implantation and at seven time points thereafter: 1 week, 1 month, 3 months, 6 months, 1 year, 18 months, and 2 years. Correlation analyses and linear mixed modeling were used to identify correlates of diuretic dose before and after LVAD implantation. Eighty two consecutive eligible patients were reviewed. The prevalence of loop diuretic use was 95% at baseline but significantly lower than that at all subsequent time points (p < 0.048 for all). Nevertheless, more than half of patients on whom we had such follow-up data were on loop diuretics two years after LVAD implantation. Average furosemide equivalent dose was significantly lower at every time point after implantation compared to baseline (p < 0.006 for all). Blood urine nitrogen (BUN) was the most robust predictor of dose after LVAD implant. The prevalence and average furosemide equivalent dose was significantly reduced after LVAD implantation, but the use of loop diuretic remained more than 50% for up to two years. Consistent association with BUN may indirectly indicate overuse of diuretics post LVAD implant.Keywords
This publication has 11 references indexed in Scilit:
- Right ventricular failure after left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2015
- Left Ventricular Assist Device Management and ComplicationsCritical Care Clinics, 2014
- Assessment and Management of Heart Failure After Left Ventricular Assist Device ImplantationCirculation, 2014
- The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summaryThe Journal of Heart and Lung Transplantation, 2013
- Efficacy and safety of loop diuretic therapy in acute decompensated heart failure: a clinical reviewHeart Failure Reviews, 2012
- Metabolic and toxicological considerations for diuretic therapy in patients with acute heart failureExpert Opinion on Drug Metabolism & Toxicology, 2011
- Management of Right Ventricular Failure in the Era of Ventricular Assist Device TherapyCurrent Heart Failure Reports, 2011
- Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2010
- Clinical management of continuous-flow left ventricular assist devices in advanced heart failureThe Journal of Heart and Lung Transplantation, 2010
- Right Ventricular Dysfunction During Intensive Pharmacologic Unloading Persists After Mechanical UnloadingJournal of Cardiac Failure, 2010