The impact of CBCT-head tilting on 3D condylar segmentation reproducibility
- 1 September 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 52 (6) , 20230072
Abstract
Objectives: To investigate whether variations in head positioning may influence the reproducibility of cone-beam CT (CBCT) three-dimensional (3D) segmented models of the mandibular condyle. Methods: Five fresh frozen cadaver heads were scanned in four different positions: reference position (RP) and a set of three tilted alternative head positions (AP) in anteroposterior direction (AP1: 2 cm anterior translation, AP2: 5° pitch rotation, AP3: 10° pitch rotation). Surface models of mandibular condyles were constructed and compared with the condylar reference position using voxel-based registration. Descriptive statistics and a linear mixed-effects model were performed to compare condylar volumetric differences and root mean square (RMS) distance between surfaces of AP vs RP. Results: The mean differences in condylar volumes of AP vs RP were 14.1 mm³ (95% CI [−79.3, 107.4]) for AP1, 1.0 mm³ (95% CI [−87.2, 89.2]) for AP2 and 0.1 mm³ (95% CI [−88.3, 88.4]) for AP3. Mean and absolute volumetric differences did not exceed earlier reported intraoperator differences of 30 mm³. The RMS distance values obtained per group were 0.12 mm (95% CI [0.05,0.20]) for AP1, 0.17 mm (95% CI [0.10, 0.22]) for AP2 and 0.17 mm for AP3 (95% CI [0.10,0.22]). The confidence intervals (CI) for RMS distance remained far below the threshold for clinical acceptability (0.5 mm). Conclusions: Within the limits of the present study, it is suggested that tilted head positions may affect the reproducibility of 3D condylar segmentation, thereby influencing outcome in repeated CBCT scanning. Nevertheless, observed differences are unlikely to have a meaningful impact on clinical patient diagnosis and management.Keywords
This publication has 36 references indexed in Scilit:
- A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandibleDentomaxillofacial Radiology, 2013
- The influence of the segmentation process on 3D measurements from cone beam computed tomography-derived surface modelsClinical Oral Investigations, 2013
- Effective dose range for dental cone beam computed tomography scannersEuropean Journal of Radiology, 2012
- Clinical Application of 3D Imaging for Assessment of Treatment OutcomesSeminars in Orthodontics, 2011
- Superimposition of 3-dimensional cone-beam computed tomography models of growing patientsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomographyClinical Oral Investigations, 2009
- Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning positionEuropean Journal of Orthodontics, 2008
- Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applicationsRadiation Protection Dosimetry, 2008
- Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomographyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006