A Pilot Study on Feasibility and Effectiveness of Intraoperative Spectral-Domain Optical Coherence Tomography in Glaucoma Procedures
Authors:
- 1 March 2015
- journal article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 4 (2) , 2
Abstract
To demonstrate the use of a spectral-domain optical coherence tomography (SDOCT) integrated surgical microscope in glaucoma surgery. An SDOCT system was used to interface directly with an ophthalmic surgical microscope, to allow real-time intraoperative SDOCT (iOCT) imaging during glaucoma procedures like phaco-trabeculectomy, Ahmed glaucoma valve (AGV) implantation, gonio-synechiolysis, and bleb needling. The various surgical steps during glaucoma surgeries where iOCT can be of potential help in guiding the surgeon were recorded. High-resolution, cross-sectional images of the relevant structures were achieved with the iOCT system in all procedures. The surgeon could determine the depth of the scleral dissection, the intrastomal bed, the path of the AGV tube in the eye, the release of peripheral anterior synechiae and the efficacy of needling with respect to breakage of loculations; most of these are technically ‘blind' procedures, where the outcomes are determined postoperatively. Metallic instruments cast a shadow on tissues below, thereby restricting the use of the device in its current state. The iOCT system provided high quality, intraoperative, real-time imaging, which could possibly improve the safety and efficacy of the surgical procedures in glaucoma. Further studies and modifications to the iOCT are required to better understand and increase the uptake of this technology in daily practice. The iOCT, with further advancements in its technology, could potentially provide the surgeon both quantitative and qualitative, real-time depth and tissue proximity details, thus improving the safety and accuracy of glaucoma surgery.Keywords
This publication has 19 references indexed in Scilit:
- UTILITY OF INTRAOPERATIVE OPTICAL COHERENCE TOMOGRAPHY DURING VITRECTOMY SURGERY FOR VITREOMACULAR TRACTION SYNDROMERetina, 2014
- Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER studyBritish Journal of Ophthalmology, 2014
- INTRASURGICAL DYNAMICS OF MACULAR HOLE SURGERYRetina, 2014
- Visualization of Real-Time Intraoperative Maneuvers with a Microscope-Mounted Spectral Domain Optical Coherence Tomography SystemRetina, 2013
- Tomographie par cohérence optique en domaine spectral du segment antérieur : la 3e dimensionJournal Français d'Ophtalmologie, 2009
- Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography ImagingOphthalmology, 2009
- INTRAOPERATIVE USE OF HANDHELD SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING IN MACULAR SURGERYRetina, 2009
- Spectral Domain Optical Coherence Tomography and GlaucomaInternational Ophthalmology Clinics, 2008
- Clinical applications and new developments of optical coherence tomography: an evidence‐based reviewClinical and Experimental Optometry, 2007
- Spectral Domain Optical Coherence TomographyArchives of Ophthalmology (1950), 2005