Abstract
This article presents some experimental data recorded from 54 impact tests on pressurized mild steel pipes. The pipes were fully clamped across a span which was ten times the outside pipe diameter of 60 mm. The pipes had a wall thickness of 1.70 mm and were impacted laterally by a rigid wedge indenter at the mid-span and one-quarter-span positions. The impact velocities ranged up to 13.6 m/s and caused large inelastic indentations for the lower values and at higher values a loss of integrity which could occur underneath the indenter and/or at an end support. The critical values for the two failure energies were obtained for a range of internal gas pressures.

This publication has 11 references indexed in Scilit: