Teat Sinus Vacua at Different Milking Machine Vacua and Pulsator Ratios

Authors:

Abstract
Nine quarters of three cows were used in measuring maximum and residual teat sinus vacua after the end of milk flow at four milking vacuum levels and two pulsator ratios. The increase in maximum and residual teat sinus vacua was nearly linear from 250 to 400 Into Jig milking vacuum. Between 400 and 500 mm Hg milking vacuum, the increase in maximum teat sinus vacuum was noulinear and increased rapidly. Congestion of the teat end and signs of discomfort to the cow were observed when the milking vacuum was 500 mm Jig. From results of this study, it would appear that a stable milking vacuum above 400 mm Itg should be avoided, because of excessive teat sinus vacuum and possible teat injury.