Cm Factor in Load and Resistance Factor Design
Authors:
- 1 August 1987
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 113 (8) , 1738-1754
Abstract
The linear approximate expression for the Cm factor used in the American Institute of Steel Construction's 1986 load and resistance factor design specification is derived on the basis of an in‐plane elastic beam‐column analysis. This expression is assumed to be conservative for the design of beamcolumns in the inelastic range, in plane and in space. In this paper, the validity of these assumptions is examined closely for box‐ and I‐shaped cross sections under uniaxial and biaxial loading conditions. It is found that the linear expression Cm=0.6-0.4(M1/M2) without the condition Cm⩾0.4 is valid for beamcolumns in plane and in space, and provides a close approximation to the exact results based on the inelastic analysis of an imperfect beam‐column, just as that based on the elastic analysis does.Keywords
This publication has 3 references indexed in Scilit:
- Inelastic lateral buckling of steel beam–columnsCanadian Journal of Civil Engineering, 1986
- Design Criteria for Box Columns Under Biaxial LoadingJournal of Structural Engineering, 1985
- The New Guide to Stability Design Criteria for Metal StructuresEngineering Journal, 1976