Smartphone System for Heart Rate and Breathing Rate Estimation
Open Access
- 11 October 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 3, 1-4
Abstract
In this short paper, we present a new method to use a smartphone placed unattached on a subject’s chest in the supine position to obtain heartbeat and breathing signals and estimate heart and breathing rates, simultaneously. We collected 3-axis accelerometer, gyroscope and magnetometer signals and performed sensor fusion to extract a user’s breathing signal and breathing rate. A hidden Markov model was used to segment the ballistocardiograph/seismocardiograph signals and extract the heart rate. The smartphone application was verified against breathing belt measurements and ECG measurements. We modified and proposed several suitable signal quality metrics for seismocardiograph signals. The overall results show that the application accurately estimated the breathing and heart rates, achieving a minimum mean percent error of 2.52% for breathing and 2.33% for heart rate. This work is a big step forward for vital sign estimation using inexpensive pervasive devices.Keywords
Funding Information
- Natural Sciences and Engineering Research Council (NSERC) of Canada
This publication has 10 references indexed in Scilit:
- Pervasive Cardiovascular and Respiratory Monitoring Devices2023
- Technical Note: Evaluation of audiovisual biofeedback smartphone application for respiratory monitoring in radiation oncologyMedical Physics, 2020
- High-Accuracy, Unsupervised Annotation of Seismocardiogram Traces for Heart Rate MonitoringIEEE Transactions on Instrumentation and Measurement, 2020
- Assessment of Ultra-Short Heart Variability Indices Derived by Smartphone Accelerometers for Stress DetectionSensors, 2019
- Inertial Sensor-Based Respiration AnalysisIEEE Transactions on Instrumentation and Measurement, 2019
- Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic VariablesScientific Reports, 2017
- A Hidden Markov Model for SeismocardiographyIEEE Transactions on Biomedical Engineering, 2017
- Beat-to-beat heart rate detection by smartphone's accelerometers: Validation with ECG2016
- Ballistocardiography — A method worth revisiting2011
- A Wavelet-Based Multisensor Data Fusion AlgorithmIEEE Transactions on Instrumentation and Measurement, 2004