Comparison of breathing tube connectors during invasive bronchial procedures*
Authors:
- 1 May 2009
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 64 (6) , 666-673
Abstract
Summary: Bronchoscopy and bronchial suctioning during intra‐operative artificial ventilation often causes leakage from the ventilation circuit with a decrease in ventilatory parameters and possible workplace contamination with anaesthetic gases. Different connectors have been developed to reduce gas leakage. We evaluated the following connectors : VBM 2 mm, 3 mm and 5 mm, Bodai Suction‐Safe, Bodai Bronch‐Safe and Bodai Trach‐Safe, as well as the BE 105‐7, BE 105‐8 and SH 7‐45. Invasive bronchial instruments (catheters, bronchoscopes and bronchial blockers) with 1.67–7.33 mm diameter were used. Pressure‐controlled ventilation was performed on a test lung using a ventilator. Sevoflurane concentration in the room was measured 0.2 and 1.5 m from the connector using a photo‐acoustic infrared‐spectroscope. The VBM connectors caused the least gas leak and ensured stability of ventilation parameters even at peak pressures when combined with smaller instruments. With instruments > 6 mm, BE 105‐7, BE 105‐8 and SH 7‐45 connectors performed best. The Bodai connectors showed a reduced ability to prevent leakage and to keep ventilatory parameters stable. All connectors, excluding the Bodai Trach‐Safe, prevented exposure to anaesthetic gases beyond the current safety recommendations when combined with the fitting instruments. The connectors showed different ranges of tightness, equivalent to different ranges of compatibility with the instruments used.Keywords
This publication has 22 references indexed in Scilit:
- Hemodynamic and respiratory changes during lung recruitment and descending optimal positive end-expiratory pressure titration in patients with acute respiratory distress syndrome*Critical Care Medicine, 2007
- Sevoflurane-induced oxidative stress and cellular injury in human peripheral polymorphonuclear neutrophilsFood and Chemical Toxicology, 2006
- Dichtigkeitsprüfung einer neuen Tubuskonnektorschleuse zur intraoperativen Bronchoskopie und AbsaugungAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 2005
- Autoantibodies Associated with Volatile Anesthetic Hepatitis Found in the Sera of a Large Cohort of Pediatric AnesthesiologistsAnesthesia & Analgesia, 2002
- Staff exposure to anaesthetic gases in theatre and non theatre areasEuropean Journal of Anaesthesiology, 2000
- Staff exposure to anaesthetic gases in theatre and non theatre areas2000
- Causes of Nitrous Oxide Contamination in Operating RoomsAnesthesiology, 1999
- Exposure of personnel to sevoflurane during paediatric anaesthesia: influence of professional role and anaesthetic procedure1999
- Occupational exposure to sevoflurane, halothane and nitrous oxide during paediatric anaesthesia Waste gas exposure during paediatric anaesthesiaAnaesthesia, 1997
- Shift Work, Nitrous Oxide Exposure and Subfertility among Swedish MidwivesInternational Journal of Epidemiology, 1996